摘要
Aiming at the velocity measurement in harsh combustion flow with high temperature and high speed, the velocity measurement method based on tunable diode laser absorption spectroscopy(TDLAS)was presented. The two-crossed-beams scanned-wavelength direct absorption spectroscopy(SDAS)system with 7185.597cm-1 as center frequency was designed for the velocity measurement of the flow in incoming simulated system, which used the combustion of kerosene fuel to heat the air. Compared with the one-dimensional theoretical calculated value and numerical simulation value, the relative deviations are less than 10%, showing that the velocity measurement using TDLAS is effective value for combustion flow.
源语言 | 英语 |
---|---|
页(从-至) | 516-520 |
页数 | 5 |
期刊 | Ranshao Kexue Yu Jishu/Journal of Combustion Science and Technology |
卷 | 21 |
期 | 6 |
DOI | |
出版状态 | 已出版 - 15 12月 2015 |