摘要
The influence of surface treatment (electroplating Cr, Cd-Ti and ion plating Al) on stress corrosion cracking (SCC) behavior of ultra-high strength steel 300 M in 3.5% NaCl solution has been studied by using slow strain rate technique (SSRT) and WOL plain strain precracked specimens. The tensile properties of 300 M steel in air influenced by surface treatment process have been determined by using SSRT. The SCC mechanism of coated 300 M steel in 3.5% NaCl solution has been proposed based on the results of artificial occluded cell tests, electrochemical measurement and fractography analysis.
源语言 | 英语 |
---|---|
页(从-至) | 49-52, 64 |
期刊 | Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University |
卷 | 32 |
期 | 6 |
出版状态 | 已出版 - 1998 |
已对外发布 | 是 |