Improvement of combustion flame thermometry based on TDLAS

Bin Yang, Bin Huang, Hui Nan Yang, Pei Jin Liu, Guo Qiang He

科研成果: 期刊稿件文章同行评审

2 引用 (Scopus)

摘要

The system with 7 153.748-7 154.354 cm-1 line-pair based on tunable diode laser absorption spectroscopy (TDLAS) is designed for temperature measurement of premixed flat flame. Due to the weak absorptions, the signal-to-noise ratios (SNR) are low, and the relative deviation between TDLAS and thermocouple are larger. Therefore, the dual lasers TDLAS system with (7 185.597-(7 444.352+7 444.371)) cm-1 line-pair, which is combined long path method, is developed for improvement of measurement accuracy. The result shows that the selected range will be broaden by using dual lasers, and the stronger line pair will be selected for improvement of SNR. Furthermore, combined the long path method, the relative deviation between TDLAS and thermocouple can be reduced from 10% to 5%.

源语言英语
页(从-至)596-601
页数6
期刊Jiliang Xuebao/Acta Metrologica Sinica
37
6
DOI
出版状态已出版 - 22 11月 2016

指纹

探究 'Improvement of combustion flame thermometry based on TDLAS' 的科研主题。它们共同构成独一无二的指纹。

引用此