Evaluation of multiple corona reactor modes and the application in odor removal

Yao Shi, Jian Jun Ruan, Xin Wang, Wei Li, Tian En Tan

科研成果: 期刊稿件文章同行评审

15 引用 (Scopus)

摘要

Effects of multiple corona reactor modes on pulse characteristics, energy transfer efficiency, and odor (H2S and NH3) removal were investigated experimentally by the wire-plate corona reactor(s). The removal efficiency of H2S was only 91% and the energy consumption was 16.1 Wh m-3 by the single mode with a gas-How rate of 23 m3h -1 and an initial concentration of 200 mg m-3. At the same experimental conditions, almost 100% removal efficiency was achieved and the energy consumption was only 12.8 and 14.9 Wh m-3 by the series and parallel modes. In the case of 50 mg m-3 NH3 removal at the same gas-flow rate, the removal efficiencies with the single mode, the series and parallel modes were 64, 92 and 70%, respectively. The energy requirement did not increase at the same residence time under the experimental conditions of the single mode with a gas-flow rate of 11.5 m3 h -1 and the series or parallel mode with a gas-flow rate of 23.0 m3 h-1. The experimental results indicate that the series and parallel modes are effective in saving energy consumption, improving removal ability and efficiency, especially for the series mode.

源语言英语
页(从-至)187-196
页数10
期刊Plasma Chemistry and Plasma Processing
26
2
DOI
出版状态已出版 - 4月 2006
已对外发布

指纹

探究 'Evaluation of multiple corona reactor modes and the application in odor removal' 的科研主题。它们共同构成独一无二的指纹。

引用此