TY - JOUR
T1 - Sensitivity Enhanced Plasmonic Biosensor Using Bi2Se3-Graphene Heterostructures
T2 - A Theoretical Analysis
AU - Du, Fusheng
AU - Zheng, Kai
AU - Zeng, Shuwen
AU - Yuan, Yufeng
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/11
Y1 - 2022/11
N2 - This study provided a theoretical insight for designing novel plasmonic biosensors using bismuth selenide (Bi2Se3)-Graphene heterostructures. It was a van der Waals (vdWs) stacked configuration composed of gold (Au) film, few quintuple layer (QL) Bi2Se3 and few-layered graphene. In particular, the proposed biosensor was created by Goos-Hänchen (GH) shift rather than phase, resulting in a more sensitive biosensing response. Under the excitation of 632.8 nm, significant sensitivity enhancement performance was obtained via varying the thickness of Bi2Se3-Graphene heterostructures. The best configuration was 32 nm Au film−2-QL Bi2Se3-3-layer graphene, generating the largest GH shift, as high as −1.0202 × 104 µm. Moreover, the highest detection sensitivity was determined to be 8.5017 × 106 µm/RIU, responding to a tiny refractive index (RI) change of 0.0012 RIU (RIU, refractive index unit). More importantly, our proposed biosensor has shown a theoretical feasibility of monitoring virus samples. For example, there was an efficient linear detection range for severe acute respiratory syndrome coronavirus 2 (SARS-CoV−2, 0~13.44 nanomole (nM)) and its Spike (S) glycoprotein (0~59.74 nM), respectively. It is expected that our proposed plasmonic biosensor has a potential application in performing sensitive detection of SARS-CoV−2.
AB - This study provided a theoretical insight for designing novel plasmonic biosensors using bismuth selenide (Bi2Se3)-Graphene heterostructures. It was a van der Waals (vdWs) stacked configuration composed of gold (Au) film, few quintuple layer (QL) Bi2Se3 and few-layered graphene. In particular, the proposed biosensor was created by Goos-Hänchen (GH) shift rather than phase, resulting in a more sensitive biosensing response. Under the excitation of 632.8 nm, significant sensitivity enhancement performance was obtained via varying the thickness of Bi2Se3-Graphene heterostructures. The best configuration was 32 nm Au film−2-QL Bi2Se3-3-layer graphene, generating the largest GH shift, as high as −1.0202 × 104 µm. Moreover, the highest detection sensitivity was determined to be 8.5017 × 106 µm/RIU, responding to a tiny refractive index (RI) change of 0.0012 RIU (RIU, refractive index unit). More importantly, our proposed biosensor has shown a theoretical feasibility of monitoring virus samples. For example, there was an efficient linear detection range for severe acute respiratory syndrome coronavirus 2 (SARS-CoV−2, 0~13.44 nanomole (nM)) and its Spike (S) glycoprotein (0~59.74 nM), respectively. It is expected that our proposed plasmonic biosensor has a potential application in performing sensitive detection of SARS-CoV−2.
KW - BiSe-Graphene heterostructures
KW - differential GH shift
KW - plasmonic biosensor
KW - ultrasensitive biosensing
UR - http://www.scopus.com/inward/record.url?scp=85142450162&partnerID=8YFLogxK
U2 - 10.3390/nano12224078
DO - 10.3390/nano12224078
M3 - 文章
AN - SCOPUS:85142450162
SN - 2079-4991
VL - 12
JO - Nanomaterials
JF - Nanomaterials
IS - 22
M1 - 4078
ER -