TY - JOUR
T1 - Research on new treatment mode of radiotherapy based on pseudo-medical images
AU - Sun, Hongfei
AU - Xi, Qianyi
AU - Sun, Jiawei
AU - Fan, Rongbo
AU - Xie, Kai
AU - Ni, Xinye
AU - Yang, Jianhua
N1 - Publisher Copyright:
© 2022
PY - 2022/6
Y1 - 2022/6
N2 - Background and objective: Multi-modal medical images with multiple feature information are beneficial for radiotherapy. A new radiotherapy treatment mode based on triangle generative adversarial network (TGAN) model was proposed to synthesize pseudo-medical images between multi-modal datasets. Methods: CBCT, MRI and CT images of 80 patients with nasopharyngeal carcinoma were selected. The TGAN model based on multi-scale discriminant network was used for data training between different image domains. The generator of the TGAN model refers to cGAN and CycleGAN, and only one generation network can establish the non-linear mapping relationship between multiple image domains. The discriminator used multi-scale discrimination network to guide the generator to synthesize pseudo-medical images that are similar to real images from both shallow and deep aspects. The accuracy of pseudo-medical images was verified in anatomy and dosimetry. Results: In the three synthetic directions, namely, CBCT → CT, CBCT → MRI, and MRI → CT, significant differences (p < 0.05) in the three-fold-cross validation results on PSNR and SSIM metrics between the pseudo-medical images obtained based on TGAN and the real images. In the testing stage, for TGAN, the MAE metric results in the three synthesis directions (CBCT → CT, CBCT → MRI, and MRI → CT) were presented as mean (standard deviation), which were 68.67 (5.83), 83.14 (8.48), and 79.96 (7.59), and the NMI metric results were 0.8643 (0.0253), 0.8051 (0.0268), and 0.8146 (0.0267) respectively. In terms of dose verification, the differences in dose distribution between the pseudo-CT obtained by TGAN and the real CT were minimal. The H values of the measurement results of dose uncertainty in PGTV, PGTVnd, PTV1, and PTV2 were 42.510, 43.121, 17.054, and 7.795, respectively (P < 0.05). The differences were statistically significant. The gamma pass rate (2%/2 mm) of pseudo-CT obtained by the new model was 94.94% (0.73%), and the numerical results were better than those of the three other comparison models. Conclusions: The pseudo-medical images acquired based on TGAN were close to the real images in anatomy and dosimetry. The pseudo-medical images synthesized by the TGAN model have good application prospects in clinical adaptive radiotherapy.
AB - Background and objective: Multi-modal medical images with multiple feature information are beneficial for radiotherapy. A new radiotherapy treatment mode based on triangle generative adversarial network (TGAN) model was proposed to synthesize pseudo-medical images between multi-modal datasets. Methods: CBCT, MRI and CT images of 80 patients with nasopharyngeal carcinoma were selected. The TGAN model based on multi-scale discriminant network was used for data training between different image domains. The generator of the TGAN model refers to cGAN and CycleGAN, and only one generation network can establish the non-linear mapping relationship between multiple image domains. The discriminator used multi-scale discrimination network to guide the generator to synthesize pseudo-medical images that are similar to real images from both shallow and deep aspects. The accuracy of pseudo-medical images was verified in anatomy and dosimetry. Results: In the three synthetic directions, namely, CBCT → CT, CBCT → MRI, and MRI → CT, significant differences (p < 0.05) in the three-fold-cross validation results on PSNR and SSIM metrics between the pseudo-medical images obtained based on TGAN and the real images. In the testing stage, for TGAN, the MAE metric results in the three synthesis directions (CBCT → CT, CBCT → MRI, and MRI → CT) were presented as mean (standard deviation), which were 68.67 (5.83), 83.14 (8.48), and 79.96 (7.59), and the NMI metric results were 0.8643 (0.0253), 0.8051 (0.0268), and 0.8146 (0.0267) respectively. In terms of dose verification, the differences in dose distribution between the pseudo-CT obtained by TGAN and the real CT were minimal. The H values of the measurement results of dose uncertainty in PGTV, PGTVnd, PTV1, and PTV2 were 42.510, 43.121, 17.054, and 7.795, respectively (P < 0.05). The differences were statistically significant. The gamma pass rate (2%/2 mm) of pseudo-CT obtained by the new model was 94.94% (0.73%), and the numerical results were better than those of the three other comparison models. Conclusions: The pseudo-medical images acquired based on TGAN were close to the real images in anatomy and dosimetry. The pseudo-medical images synthesized by the TGAN model have good application prospects in clinical adaptive radiotherapy.
KW - Generative adversarial network
KW - Pseudo medical images
KW - Radiotherapy
UR - http://www.scopus.com/inward/record.url?scp=85131450655&partnerID=8YFLogxK
U2 - 10.1016/j.cmpb.2022.106932
DO - 10.1016/j.cmpb.2022.106932
M3 - 文章
C2 - 35671601
AN - SCOPUS:85131450655
SN - 0169-2607
VL - 221
JO - Computer Methods and Programs in Biomedicine
JF - Computer Methods and Programs in Biomedicine
M1 - 106932
ER -