TY - JOUR
T1 - Reconstruction method for gamma-ray coded-aperture imaging based on mask and anti-mask functions
AU - Fan, Donghai
AU - Wu, Rui
AU - Wei, Dengke
AU - Li, Yingrui
AU - Tan, Tingting
AU - Zha, Gangqiang
N1 - Publisher Copyright:
© 2024
PY - 2024/8
Y1 - 2024/8
N2 - Gamma-ray coded-aperture imaging technology plays an important role in nuclear security, decommissioning of nuclear facilities, and nuclear medicine diagnosis. However, under near-field imaging condition, artifacts in the reconstructed image can interfere with identifying the shape and position of the radioactive source. In this paper, a gamma-ray coded-aperture imaging method based on mask and anti-mask functions was proposed to suppress imaging artifacts and speed up the acquisition of low-noise reconstructed images. Through simulation, the effects of the number of iterations and the thickness of the coded-aperture collimator on the imaging quality were studied, and the range of the optimal correction factor in the method was determined. Imaging experiments were conducted using a compact coded-aperture gamma camera based on CdZnTe detector to verify the applicability of the optimal correction factor range. The limitations of the proposed method were analyzed through complex-shaped source imaging simulations and multi-source imaging experiments. This method has an insufficient suppression effect on random artifacts and requires further improvement in imaging irregular radioactive sources. However, it has good imaging performance for single-point source and multi-point sources, effectively reducing regular cross-shaped and stripe-like artifacts. In the non-uniform radioactive background, it can eliminate a part of artifacts, significantly improving imaging quality. Therefore, this method has potential applications in complex radioactive environments.
AB - Gamma-ray coded-aperture imaging technology plays an important role in nuclear security, decommissioning of nuclear facilities, and nuclear medicine diagnosis. However, under near-field imaging condition, artifacts in the reconstructed image can interfere with identifying the shape and position of the radioactive source. In this paper, a gamma-ray coded-aperture imaging method based on mask and anti-mask functions was proposed to suppress imaging artifacts and speed up the acquisition of low-noise reconstructed images. Through simulation, the effects of the number of iterations and the thickness of the coded-aperture collimator on the imaging quality were studied, and the range of the optimal correction factor in the method was determined. Imaging experiments were conducted using a compact coded-aperture gamma camera based on CdZnTe detector to verify the applicability of the optimal correction factor range. The limitations of the proposed method were analyzed through complex-shaped source imaging simulations and multi-source imaging experiments. This method has an insufficient suppression effect on random artifacts and requires further improvement in imaging irregular radioactive sources. However, it has good imaging performance for single-point source and multi-point sources, effectively reducing regular cross-shaped and stripe-like artifacts. In the non-uniform radioactive background, it can eliminate a part of artifacts, significantly improving imaging quality. Therefore, this method has potential applications in complex radioactive environments.
KW - CdZnTe detector
KW - Coded-aperture
KW - Gamma-ray imaging
KW - Imaging artifacts
UR - http://www.scopus.com/inward/record.url?scp=85197021858&partnerID=8YFLogxK
U2 - 10.1016/j.radmeas.2024.107210
DO - 10.1016/j.radmeas.2024.107210
M3 - 文章
AN - SCOPUS:85197021858
SN - 1350-4487
VL - 176
JO - Radiation Measurements
JF - Radiation Measurements
M1 - 107210
ER -