Measurements of heat transfer coefficient and film cooling effectiveness distribution on a vane using transient liquid crystal technique

Jiangtao Bai, Huiren Zhu, Zongwei Zhang, Duchun Xu

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

The Heat transfer coefficient and the film cooling effectiveness were measured on a turbine NGV airfoil employing the transient liquid crystal technique. There are five rows of compound angle cylinder film holes on the showerhead, 10 rows of cylinder holes on the pressure side, two rows of cylinder holes and two rows of fan-shaped holes on the suction side. All the film cooling gas are supplied by two plenums. The measurements were conducted for a three-vane linear cascade at an inlet Reynolds number of 1.1×105, a mass flow ratio of 5.87% in the first plenum and 1.06% in the second plenum. Detailed distributions of the heat transfer coefficient and the film cooling effectiveness were obtained. The result shows that the heat transfer coefficient and the film cooling effectiveness are higher in the near hole region, and the fan-shaped hole displays higher film cooling effectiveness than the cylinder hole. The film cover region shrinks on the suction side and expands on the pressure side by the influence of passage vortex. In addition, the heat transfer distribution on the suction side is influenced by the flow separation and the passage vortex.

Original languageEnglish
Pages (from-to)92-97
Number of pages6
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume44
Issue number11
StatePublished - Nov 2010

Keywords

  • Film cooling
  • Heat transfer coefficient
  • Liquid crystal
  • Transient measurement
  • Vane

Fingerprint

Dive into the research topics of 'Measurements of heat transfer coefficient and film cooling effectiveness distribution on a vane using transient liquid crystal technique'. Together they form a unique fingerprint.

Cite this