TY - JOUR
T1 - Comparing model-based adaptive LMS filters and a model-free hysteresis loop analysis method for structural health monitoring
AU - Zhou, Cong
AU - Chase, J. Geoffrey
AU - Rodgers, Geoffrey W.
AU - Xu, Chao
N1 - Publisher Copyright:
© 2016 Elsevier Ltd
PY - 2017/2/1
Y1 - 2017/2/1
N2 - The model-free hysteresis loop analysis (HLA) method for structural health monitoring (SHM) has significant advantages over the traditional model-based SHM methods that require a suitable baseline model to represent the actual system response. This paper provides a unique validation against both an experimental reinforced concrete (RC) building and a calibrated numerical model to delineate the capability of the model-free HLA method and the adaptive least mean squares (LMS) model-based method in detecting, localizing and quantifying damage that may not be visible, observable in overall structural response. Results clearly show the model-free HLA method is capable of adapting to changes in how structures transfer load or demand across structural elements over time and multiple events of different size. However, the adaptive LMS model-based method presented an image of greater spread of lesser damage over time and story when the baseline model is not well defined. Finally, the two algorithms are tested over a simpler hysteretic behaviour typical steel structure to quantify the impact of model mismatch between the baseline model used for identification and the actual response. The overall results highlight the need for model-based methods to have an appropriate model that can capture the observed response, in order to yield accurate results, even in small events where the structure remains linear.
AB - The model-free hysteresis loop analysis (HLA) method for structural health monitoring (SHM) has significant advantages over the traditional model-based SHM methods that require a suitable baseline model to represent the actual system response. This paper provides a unique validation against both an experimental reinforced concrete (RC) building and a calibrated numerical model to delineate the capability of the model-free HLA method and the adaptive least mean squares (LMS) model-based method in detecting, localizing and quantifying damage that may not be visible, observable in overall structural response. Results clearly show the model-free HLA method is capable of adapting to changes in how structures transfer load or demand across structural elements over time and multiple events of different size. However, the adaptive LMS model-based method presented an image of greater spread of lesser damage over time and story when the baseline model is not well defined. Finally, the two algorithms are tested over a simpler hysteretic behaviour typical steel structure to quantify the impact of model mismatch between the baseline model used for identification and the actual response. The overall results highlight the need for model-based methods to have an appropriate model that can capture the observed response, in order to yield accurate results, even in small events where the structure remains linear.
KW - Adaptive filter
KW - Damage identification
KW - Hysteresis loop analysis
KW - Model-based
KW - Reinforced concrete experimental structure
KW - Structural health monitoring
UR - http://www.scopus.com/inward/record.url?scp=84991832991&partnerID=8YFLogxK
U2 - 10.1016/j.ymssp.2016.07.030
DO - 10.1016/j.ymssp.2016.07.030
M3 - 文章
AN - SCOPUS:84991832991
SN - 0888-3270
VL - 84
SP - 384
EP - 398
JO - Mechanical Systems and Signal Processing
JF - Mechanical Systems and Signal Processing
ER -