Ablation resistance of SiC-ZrC coating prepared by a simple two-step method on carbon fiber reinforced composites

Xiao Hong Shi, Jun Hao Huo, Jun Liang Zhu, Lei Liu, He Jun Li, Xiao Jun Hu, Meng Yan Li, Ling Jun Guo, Qian Gang Fu

Research output: Contribution to journalArticlepeer-review

66 Scopus citations

Abstract

SiC-ZrC ablation resistance coating was prepared on the surface of carbon fiber reinforced carbon (C/C) composites by simple pack cementation combined with low-cost slurry infiltration method. The results showed that SiC-ZrC coating could effectively protect C/C composites from ablation for 45s at 3723K under oxyacetylene torch. The mass and linear ablation rates (0.038±0.01mg/(scm2) and 2.42±0.15μm/s) were largely reduced compared with that of uncoated C/C composites (0.530±0.01mg/(scm2) and 1.75±0.15μm/s) after ablation for 20s. The good ablation protective ability of SiC-ZrC coating is mainly attributed to the volatilization of SiO2 and the formation of ZrO2.

Original languageEnglish
Pages (from-to)49-55
Number of pages7
JournalCorrosion Science
Volume88
DOIs
StatePublished - Nov 2014

Keywords

  • A. Ceramic matrix composites
  • A. Zirconium
  • B. SEM
  • C. High temperature corrosion

Fingerprint

Dive into the research topics of 'Ablation resistance of SiC-ZrC coating prepared by a simple two-step method on carbon fiber reinforced composites'. Together they form a unique fingerprint.