TY - JOUR
T1 - Water cooling structure design and temperature field analysis of permanent magnet synchronous motor for underwater unmanned vehicle
AU - Chen, Wenwen
AU - Mao, Zhaoyong
AU - Tian, Wenlong
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2024/3/1
Y1 - 2024/3/1
N2 - Unmanned underwater vehicles (UUVs) have extremely harsh cooling conditions for permanent magnet synchronous motor (PMSM) due to global sealing and compact space, and an efficient heat dissipation system is essential for the safety and operational reliability of PMSM. Currently, with the introduction of seawater and the addition of heat exchanger, liquid reservoir are typically used for open-circuit heat dissipation, which not only adds weight, but seriously affects the flow characteristics of the UUV. In this paper, a novel dual channel water cooling structure is designed to achieve internal circulating heat dissipation without additional auxiliary devices. The temperature field of the PMSM with different water cooling structures is solved by Computational Fluid Dynamics (CFD) under rated operating conditions. The results show that the cooling efficiency of water cooling structures is more affected by low flow rates, accompanied by increasing the flow rate from 0.5 L/min to 24 L/min, the cooling performance is enhanced, but does not entirely obey a strict linear variation. Furthermore, at a flow rate of 6 L/min, the dual spiral water cooling structure performs the best heat dissipation, the maximum operating temperature of the PMSM is reduced by 51.72 K, the maximum temperature rise suppression rate reaches 53.02 %, and the minimum differential pressure of 10.18 kPa.
AB - Unmanned underwater vehicles (UUVs) have extremely harsh cooling conditions for permanent magnet synchronous motor (PMSM) due to global sealing and compact space, and an efficient heat dissipation system is essential for the safety and operational reliability of PMSM. Currently, with the introduction of seawater and the addition of heat exchanger, liquid reservoir are typically used for open-circuit heat dissipation, which not only adds weight, but seriously affects the flow characteristics of the UUV. In this paper, a novel dual channel water cooling structure is designed to achieve internal circulating heat dissipation without additional auxiliary devices. The temperature field of the PMSM with different water cooling structures is solved by Computational Fluid Dynamics (CFD) under rated operating conditions. The results show that the cooling efficiency of water cooling structures is more affected by low flow rates, accompanied by increasing the flow rate from 0.5 L/min to 24 L/min, the cooling performance is enhanced, but does not entirely obey a strict linear variation. Furthermore, at a flow rate of 6 L/min, the dual spiral water cooling structure performs the best heat dissipation, the maximum operating temperature of the PMSM is reduced by 51.72 K, the maximum temperature rise suppression rate reaches 53.02 %, and the minimum differential pressure of 10.18 kPa.
KW - Dual channel water cooling structure design
KW - Fluid-solid coupling
KW - Internal circulation heat dissipation
KW - Permanent magnet synchronous motor
KW - Temperature field distribution
UR - http://www.scopus.com/inward/record.url?scp=85180930853&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2023.122243
DO - 10.1016/j.applthermaleng.2023.122243
M3 - 文章
AN - SCOPUS:85180930853
SN - 1359-4311
VL - 240
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 122243
ER -