N2 - The novel staggered flow alternation structure (SFAS) proposed in prior study has proved to be an efficient way in improving the overall thermal performance with acceptable pressure drop penalty in Double-layer Microchannel Heat Sinks (DMHSs). Based on the prior design, a further numerical investigation concerning the optimum location of SFAS in DMHSs is presented. The corresponding temperature fields, Nusselt number, flow fields, pressure drop and thermal characteristics are presented through verified computational mode. In addition, the effect of flow arrangements such as concurrent, upper-inlet/lower-inlet countercurrent arrangement on the thermal performance are studied in more details. The best thermal location of SFAS in the DMHSs is found to be based on the alterable locations and multi-flow directions. Yet, changing the location of staggered alternation structure does not lead to an appreciable rise of pressure drop penalty in DMHSs. However, the improvement in thermal performance for upper-inlet countercurrent arrangement is significant. Placing the SFAS in the middle of the DMHSs ensures the best overall thermal performance.
AB - The novel staggered flow alternation structure (SFAS) proposed in prior study has proved to be an efficient way in improving the overall thermal performance with acceptable pressure drop penalty in Double-layer Microchannel Heat Sinks (DMHSs). Based on the prior design, a further numerical investigation concerning the optimum location of SFAS in DMHSs is presented. The corresponding temperature fields, Nusselt number, flow fields, pressure drop and thermal characteristics are presented through verified computational mode. In addition, the effect of flow arrangements such as concurrent, upper-inlet/lower-inlet countercurrent arrangement on the thermal performance are studied in more details. The best thermal location of SFAS in the DMHSs is found to be based on the alterable locations and multi-flow directions. Yet, changing the location of staggered alternation structure does not lead to an appreciable rise of pressure drop penalty in DMHSs. However, the improvement in thermal performance for upper-inlet countercurrent arrangement is significant. Placing the SFAS in the middle of the DMHSs ensures the best overall thermal performance.
KW - Double-layer microchannel heat sinks
KW - Local position
KW - Multi-flow direction
KW - Staggered flow alternation structure
KW - Thermal resistance
UR - http://www.scopus.com/inward/record.url?scp=85072176877&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2019.114332
DO - 10.1016/j.applthermaleng.2019.114332
M3 - 文章
AN - SCOPUS:85072176877
SN - 1359-4311
VL - 163
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 114332
ER -