TY - JOUR
T1 - Performances of One-Dimensional Sonomyography and Surface Electromyography in Tracking Guided Patterns of Wrist Extension
AU - Guo, Jing Yi
AU - Zheng, Yong Ping
AU - Huang, Qing Hua
AU - Chen, Xin
AU - He, Jun Feng
AU - Lai-Wa Chan, Helen
PY - 2009/6
Y1 - 2009/6
N2 - Electromyography (EMG) and ultrasonography have been widely used for skeletal muscle assessment. Recently, it has been demonstrated that the muscle thickness change collected by ultrasound during contraction, namely sonomyography (SMG), can also be used for assessment of muscles and has the potential for prosthetic control. In this study, the performances of one-dimensional sonomyography (1D SMG) and surface EMG (SEMG) signal in tracking the guided patterns of wrist extension were evaluated and compared, and the potential of 1D SMG for skeletal muscle assessment and prosthetic control was investigated. Sixteen adult normal subjects including eight males and eight females participated in the experiment. The subject was instructed to perform the wrist extension under the guidance of displayed sinusoidal, square and triangular waveforms at movement rates of 20, 30, 50 cycles per min. SMG and SEMG root mean squares (RMS) were collected from the extensor carpi radialis, respectively, and their RMS errors in relation to the guiding signals were calculated and compared. It was found that the mean RMS tracking errors of SMG under different movement rates were 18.9% ± 2.6% (mean ± SD), 18.3% ± 4.5%, and 17.0% ± 3.4% for sinusoidal, square and triangular guiding waveforms, while the corresponding values for SEMG were 30.3% ± 0.4%, 29.0% ± 2.7% and 24.7% ± 0.7%, respectively. Paired t test showed that the RMS errors of SMG tracking were significantly smaller than those of SEMG. Significant differences in RMS tracking errors of SMG among the three movement rates (p < 0.01) for all the guiding waveforms were also observed using one-way analysis of variance (ANOVA). The results suggest that SMG signal, based on further improvement, has great potential to be an alternative method to SEMG to evaluate muscle function and control prostheses. (E-mail: ypzheng@ieee.org).
AB - Electromyography (EMG) and ultrasonography have been widely used for skeletal muscle assessment. Recently, it has been demonstrated that the muscle thickness change collected by ultrasound during contraction, namely sonomyography (SMG), can also be used for assessment of muscles and has the potential for prosthetic control. In this study, the performances of one-dimensional sonomyography (1D SMG) and surface EMG (SEMG) signal in tracking the guided patterns of wrist extension were evaluated and compared, and the potential of 1D SMG for skeletal muscle assessment and prosthetic control was investigated. Sixteen adult normal subjects including eight males and eight females participated in the experiment. The subject was instructed to perform the wrist extension under the guidance of displayed sinusoidal, square and triangular waveforms at movement rates of 20, 30, 50 cycles per min. SMG and SEMG root mean squares (RMS) were collected from the extensor carpi radialis, respectively, and their RMS errors in relation to the guiding signals were calculated and compared. It was found that the mean RMS tracking errors of SMG under different movement rates were 18.9% ± 2.6% (mean ± SD), 18.3% ± 4.5%, and 17.0% ± 3.4% for sinusoidal, square and triangular guiding waveforms, while the corresponding values for SEMG were 30.3% ± 0.4%, 29.0% ± 2.7% and 24.7% ± 0.7%, respectively. Paired t test showed that the RMS errors of SMG tracking were significantly smaller than those of SEMG. Significant differences in RMS tracking errors of SMG among the three movement rates (p < 0.01) for all the guiding waveforms were also observed using one-way analysis of variance (ANOVA). The results suggest that SMG signal, based on further improvement, has great potential to be an alternative method to SEMG to evaluate muscle function and control prostheses. (E-mail: ypzheng@ieee.org).
KW - Electromyography
KW - EMG
KW - Muscle
KW - Prosthetic control
KW - SMG
KW - Sonomyography
KW - Ultrasound
UR - http://www.scopus.com/inward/record.url?scp=67349223964&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2008.11.017
DO - 10.1016/j.ultrasmedbio.2008.11.017
M3 - 文章
C2 - 19329244
AN - SCOPUS:67349223964
SN - 0301-5629
VL - 35
SP - 894
EP - 902
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 6
ER -