摘要
As the research object of inducer and impeller combination aero fuel centrifugal pumps, the outlet clearance optimization on axial-force of the pump was carried out. Through comparing the axial-force simulation data with theoretical calculation data, the axial-force trends of the two methods were identified similar and the simulation's accuracy was verified by Pumplinx because of the error less than 4%. Then the outlet clearance's influence on axial-force was analyzed. Simulation results show that expanding the clearance to 0.2 mm increases the axial-force value, and reduces the pressure charging; but reducing the clearance to 0.1 mm and 0.13 mm can make optimizations of the axial-force, and the clearance of 0.1 mm is the best. The axial-force performance of the model with clearance of 0.1 mm was analyzed finally, showing that this model's inner performance of different sections is normal and steady; the axial-force value at design point is 3 620 N, so reducing the outlet clearance to 0.1 mm can make a high optimization about axial-force of the inducer and impeller combination centrifugal pump.
源语言 | 英语 |
---|---|
页(从-至) | 2765-2772 |
页数 | 8 |
期刊 | Hangkong Dongli Xuebao/Journal of Aerospace Power |
卷 | 31 |
期 | 11 |
DOI | |
出版状态 | 已出版 - 1 11月 2016 |