N2 - Xylene is a widely used solvent and industrial chemical, but it is also considered to be a volatile organic compound (VOC) pollutant. Meanwhile, non-thermal plasma (NTP) is a potential method for remediating VOC contaminants, especially aromatic hydrocarbons. During NTP degradation of xylene, the different oxidation mechanisms of three isomers, p-xylene, o-xylene and m-xylene, have attracted lots of attention but not been studied at the molecular level. In this study, the individual degradation rates of xylene isomers in a NTP system are measured. The results show the oxidation degradation rates have the following order: o-xylene > p-xylene ≈ m-xylene. Molecular dynamics simulations with an applied external electric field were adopted to examine the oxidation process of xylene isomers, as well. The oxidation rates from the simulations were calculated, the order of which is in a good agreement with the experimental results. The oxidation pathways of xylene isomers were analyzed more thoroughly to explain the rate differences. The external electrical field is found to have two effects: one is to speed up the oxidation rate of xylene isomers overall, and the other is to alter the oxidation pathways to increase the probability of the faster ring cleavage pathways of o-xylene.
AB - Xylene is a widely used solvent and industrial chemical, but it is also considered to be a volatile organic compound (VOC) pollutant. Meanwhile, non-thermal plasma (NTP) is a potential method for remediating VOC contaminants, especially aromatic hydrocarbons. During NTP degradation of xylene, the different oxidation mechanisms of three isomers, p-xylene, o-xylene and m-xylene, have attracted lots of attention but not been studied at the molecular level. In this study, the individual degradation rates of xylene isomers in a NTP system are measured. The results show the oxidation degradation rates have the following order: o-xylene > p-xylene ≈ m-xylene. Molecular dynamics simulations with an applied external electric field were adopted to examine the oxidation process of xylene isomers, as well. The oxidation rates from the simulations were calculated, the order of which is in a good agreement with the experimental results. The oxidation pathways of xylene isomers were analyzed more thoroughly to explain the rate differences. The external electrical field is found to have two effects: one is to speed up the oxidation rate of xylene isomers overall, and the other is to alter the oxidation pathways to increase the probability of the faster ring cleavage pathways of o-xylene.
KW - MD simulation
KW - Non-thermal plasma
KW - Oxidation pathway
KW - Xylene isomers
UR - http://www.scopus.com/inward/record.url?scp=85064343998&partnerID=8YFLogxK
U2 - 10.1007/s11090-019-09986-5
DO - 10.1007/s11090-019-09986-5
M3 - 文章
AN - SCOPUS:85064343998
SN - 0272-4324
VL - 39
SP - 863
EP - 876
JO - Plasma Chemistry and Plasma Processing
JF - Plasma Chemistry and Plasma Processing
IS - 4
ER -