Influence of exit flow type on heat transfer of array impingement

Ke Fei Wang, Hui Ren Zhu, Zhong Zhou Li, Du Chun Xu

科研成果: 期刊稿件文章同行评审

2 引用 (Scopus)

摘要

A transient liquid crystal technique was used to measure the local heat transfer coefficients on a target surface with array impingement hole. The effects of jet Reynolds number (5000, 10000, 15000, 20000, 25000) and three different exit flow types on the heat transfer coefficients were also investigated. Results show that, the average heat transfer coefficient of target plate with double-sided flow is higher than that with single-sided flow;due to the different strengths of crossflow, the heat transfer coefficients on the target plate are also different. For each exit flow type, the local heat transfer coefficient increases with the jet Reynolds number over entire impingement target plate.

源语言英语
页(从-至)2273-2278
页数6
期刊Hangkong Dongli Xuebao/Journal of Aerospace Power
25
10
出版状态已出版 - 10月 2010