TY - JOUR
T1 - Highly Sensitive Strain Sensor Based on a Stretchable and Conductive Poly(vinyl alcohol)/Phytic Acid/NH2-POSS Hydrogel with a 3D Microporous Structure
AU - Shao, Liang
AU - Li, Ying
AU - Ma, Zhonglei
AU - Bai, Yang
AU - Wang, Jie
AU - Zeng, Peiyun
AU - Gong, Pin
AU - Shi, Fuxiong
AU - Ji, Zhanyou
AU - Qiao, Yang
AU - Xu, Ran
AU - Xu, Juanjuan
AU - Zhang, Guohong
AU - Wang, Caiyun
AU - Ma, Jianzhong
N1 - Publisher Copyright:
Copyright © 2020 American Chemical Society.
PY - 2020/6/10
Y1 - 2020/6/10
N2 - Conductive hydrogel-based wearable strain sensors with tough, stretchable, self-recoverable, and highly sensitive properties are highly demanded for applications in electronic skin and human-machine interface. However, currently, hydrogel-based strain sensors put forward higher requirements on their biocompatibility, mechanical strength, and sensitivity. Herein, we report a poly(vinyl alcohol)/phytic acid/amino-polyhedral oligomeric silsesquioxane (PVA/PA/NH2-POSS) conductive composite hydrogel prepared via a facile freeze-thaw cycle method. Within this hydrogel, PA acts as a cross-linking agent and ionizes hydrogen ions to endow the material with ionic conductivity, while NH2-POSS acts as a second cross-linking agent by increasing the cross-linking density of the three-dimensional network structure. The effect of the content of NH2-POSS is investigated, and the composite hydrogel with 2 wt % NH2-POSS displays a uniform and dense three-dimensional (3D) network microporous structure, high conductivity of 2.41 S/m, and tensile strength and elongation at break of 361 kPa and 363%, respectively. This hydrogel is biocompatible and has demonstrated the application as a strain sensor monitoring different human movements. The assembled sensor is stretchable, self-recoverable, and highly sensitive with fast response time (220 ms) and excellent sensitivity (GF = 3.44).
AB - Conductive hydrogel-based wearable strain sensors with tough, stretchable, self-recoverable, and highly sensitive properties are highly demanded for applications in electronic skin and human-machine interface. However, currently, hydrogel-based strain sensors put forward higher requirements on their biocompatibility, mechanical strength, and sensitivity. Herein, we report a poly(vinyl alcohol)/phytic acid/amino-polyhedral oligomeric silsesquioxane (PVA/PA/NH2-POSS) conductive composite hydrogel prepared via a facile freeze-thaw cycle method. Within this hydrogel, PA acts as a cross-linking agent and ionizes hydrogen ions to endow the material with ionic conductivity, while NH2-POSS acts as a second cross-linking agent by increasing the cross-linking density of the three-dimensional network structure. The effect of the content of NH2-POSS is investigated, and the composite hydrogel with 2 wt % NH2-POSS displays a uniform and dense three-dimensional (3D) network microporous structure, high conductivity of 2.41 S/m, and tensile strength and elongation at break of 361 kPa and 363%, respectively. This hydrogel is biocompatible and has demonstrated the application as a strain sensor monitoring different human movements. The assembled sensor is stretchable, self-recoverable, and highly sensitive with fast response time (220 ms) and excellent sensitivity (GF = 3.44).
KW - amino-polyhedral oligomeric silsesquioxane
KW - conductive hydrogel
KW - phytic acid
KW - poly(vinyl alcohol)
KW - strain sensor
UR - http://www.scopus.com/inward/record.url?scp=85086346314&partnerID=8YFLogxK
U2 - 10.1021/acsami.0c07717
DO - 10.1021/acsami.0c07717
M3 - 文章
C2 - 32406670
AN - SCOPUS:85086346314
SN - 1944-8244
VL - 12
SP - 26496
EP - 26508
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 23
ER -