TY - JOUR
T1 - Extending Hypochlorite Sensing from Cells to Elesclomol-Treated Tumors in Vivo by Using a Near-Infrared Dual-Phosphorescent Nanoprobe
AU - Meng, Xiangchun
AU - Shi, Yuxiang
AU - Chen, Zejing
AU - Song, Linna
AU - Zhao, Menglong
AU - Zou, Liang
AU - Liu, Shujuan
AU - Huang, Wei
AU - Zhao, Qiang
N1 - Publisher Copyright:
© 2018 American Chemical Society.
PY - 2018/10/24
Y1 - 2018/10/24
N2 - Reactive oxygen species (ROS), when beyond the threshold, can exhaust the capacity of cellular antioxidants and ultimately trigger cell apoptosis in tumor biology. However, the roles of hypochlorite (ClO-) in this process are much less clear compared with those of ROS, and its detection is easily obstructed by tissue penetration and endogenous fluorophores. Herein, we first synthesized a near-infrared (NIR) ratiometric ClO- probe (Ir NP) composed of two kinds of phosphorescent iridium(III) complexes (Ir1 and Ir2) encapsulated with amphiphilic DSPE-mPEG5000. Ir NPs are dual-emissive and show obvious changes in phosphorescence intensity ratios and lifetimes of two emission bands upon exposure to ClO-. During the ClO- detection, ratiometric photoluminescence imaging is much more reliable over the intensity-based one for its self-calibration, while time-resolved photoluminescence imaging (TRPI) could distinguish the phosphorescence with long lifetime of Ir NPs from short-lived autofluorescence of tissues, resulting in the high accuracy of ClO- determination. With NIR emission, a long phosphorescence lifetime, fast response, and excellent biocompatibility, Ir NPs were applied to the detection of ClO- in vitro and in vivo by means of ratiometric phosphorescence imaging and TRPI with high signal-to noise-ratios (SNR). Importantly, we demonstrated the elevated ClO- in elesclomol-stimulated tumors in living mice for the first time, which holds great potential for the visualization of the boost of ClO- in anti-carcinogen-treated tumors and the further investigation of ROS-related oncotherapeutics.
AB - Reactive oxygen species (ROS), when beyond the threshold, can exhaust the capacity of cellular antioxidants and ultimately trigger cell apoptosis in tumor biology. However, the roles of hypochlorite (ClO-) in this process are much less clear compared with those of ROS, and its detection is easily obstructed by tissue penetration and endogenous fluorophores. Herein, we first synthesized a near-infrared (NIR) ratiometric ClO- probe (Ir NP) composed of two kinds of phosphorescent iridium(III) complexes (Ir1 and Ir2) encapsulated with amphiphilic DSPE-mPEG5000. Ir NPs are dual-emissive and show obvious changes in phosphorescence intensity ratios and lifetimes of two emission bands upon exposure to ClO-. During the ClO- detection, ratiometric photoluminescence imaging is much more reliable over the intensity-based one for its self-calibration, while time-resolved photoluminescence imaging (TRPI) could distinguish the phosphorescence with long lifetime of Ir NPs from short-lived autofluorescence of tissues, resulting in the high accuracy of ClO- determination. With NIR emission, a long phosphorescence lifetime, fast response, and excellent biocompatibility, Ir NPs were applied to the detection of ClO- in vitro and in vivo by means of ratiometric phosphorescence imaging and TRPI with high signal-to noise-ratios (SNR). Importantly, we demonstrated the elevated ClO- in elesclomol-stimulated tumors in living mice for the first time, which holds great potential for the visualization of the boost of ClO- in anti-carcinogen-treated tumors and the further investigation of ROS-related oncotherapeutics.
KW - dual-phosphorescent nanoprobe
KW - elesclomol-treated tumors
KW - hypochlorite
KW - iridium(III) complexes
KW - near-infrared emission
UR - http://www.scopus.com/inward/record.url?scp=85055203605&partnerID=8YFLogxK
U2 - 10.1021/acsami.8b14717
DO - 10.1021/acsami.8b14717
M3 - 文章
C2 - 30260621
AN - SCOPUS:85055203605
SN - 1944-8244
VL - 10
SP - 35838
EP - 35846
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 42
ER -