TY - JOUR
T1 - Erratum to
T2 - Studies on the deep-level defects in CdZnTe crystals grown by travelling heater method: Deep-level defects in CdZnTe grown by travelling heater method (physica status solidi (a), (2017), 214, 5, (1600748), 10.1002/pssa.201600748)
AU - Zhou, Boru
AU - Jie, Wanqi
AU - Wang, Tao
AU - Xu, Lingyan
AU - Yang, Fan
AU - Yin, Liying
AU - Fu, Xu
AU - Nan, Ruihua
N1 - Publisher Copyright:
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2017/10
Y1 - 2017/10
N2 - The resistivity shown in Table was bulk resistivity, taken from Fig. 3 in our paper, instead of the Hall resistivity. To make it clear, we added the bulk resistivity and Hall resistivity in Table (see below). The difference between bulk resistivity and Hall resistivity is discussed. The affected sentences in the Results and discussion are also improved. 2 Hall results and bulk resistivities of CZT samples from different regions of the as-grown ingot (Table presented.) 3 Results and discussion The sentence “The I–V results shown in Fig. 3 indicate that high resistivity of ∼109 Ω cm is obtained.” is replaced with the sentences “The I–V results shown in Fig. 3 indicate that high resistivity of ∼109 Ω cm is obtained, which is different from the Hall resistivity shown in Table. For high resistive CZT, the surface states of samples may influence much in the Hall measurement. Therefore, Hall resistivity and carrier concentration taken from the Hall measurements are only used qualitatively to indicate difference from the tip to tail part of the as-grown ingot. The bulk resistivity used here was by I–V analysis, which we think can reflect more clearly genuine resistivity for high resistive CZT”. The sentences “The mobility for electrons is obtained by the expression for mobility, which is μ=d/trE (cm2 V−1 s−1) (where d is the thickness of the detector, tR is the carrier transit time, and E is the electric field strength).” are added in the front of the sentence “As shown in Fig. 4, the mobility for electrons increases significantly from 634 ± 26 cm2V−1 s−1 in the tip sample to 860 ± 10 cm2V−1 s−1 in the tail sample,”.
AB - The resistivity shown in Table was bulk resistivity, taken from Fig. 3 in our paper, instead of the Hall resistivity. To make it clear, we added the bulk resistivity and Hall resistivity in Table (see below). The difference between bulk resistivity and Hall resistivity is discussed. The affected sentences in the Results and discussion are also improved. 2 Hall results and bulk resistivities of CZT samples from different regions of the as-grown ingot (Table presented.) 3 Results and discussion The sentence “The I–V results shown in Fig. 3 indicate that high resistivity of ∼109 Ω cm is obtained.” is replaced with the sentences “The I–V results shown in Fig. 3 indicate that high resistivity of ∼109 Ω cm is obtained, which is different from the Hall resistivity shown in Table. For high resistive CZT, the surface states of samples may influence much in the Hall measurement. Therefore, Hall resistivity and carrier concentration taken from the Hall measurements are only used qualitatively to indicate difference from the tip to tail part of the as-grown ingot. The bulk resistivity used here was by I–V analysis, which we think can reflect more clearly genuine resistivity for high resistive CZT”. The sentences “The mobility for electrons is obtained by the expression for mobility, which is μ=d/trE (cm2 V−1 s−1) (where d is the thickness of the detector, tR is the carrier transit time, and E is the electric field strength).” are added in the front of the sentence “As shown in Fig. 4, the mobility for electrons increases significantly from 634 ± 26 cm2V−1 s−1 in the tip sample to 860 ± 10 cm2V−1 s−1 in the tail sample,”.
UR - http://www.scopus.com/inward/record.url?scp=85030996568&partnerID=8YFLogxK
U2 - 10.1002/pssa.201770163
DO - 10.1002/pssa.201770163
M3 - 评论/辩论
AN - SCOPUS:85030996568
SN - 1862-6300
VL - 214
JO - Physica Status Solidi (A) Applications and Materials Science
JF - Physica Status Solidi (A) Applications and Materials Science
IS - 10
M1 - 1770163
ER -