TY - JOUR
T1 - Enzymatic biosensor based on dendritic gold nanostructure and enzyme precipitation coating for glucose sensing and detection
AU - Bi, Ran
AU - Ma, Xiaoyan
AU - Miao, Kunpeng
AU - Ma, Pengcheng
AU - Wang, Qianqian
N1 - Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2023/1
Y1 - 2023/1
N2 - With the development of blood glucose monitoring medical devices, higher requirements are put forward for the sensitivity and detection limit of biosensors. Herein, a high-performance flexible enzymatic glucose biosensor was prepared by electrochemical deposition of dendritic gold nanostructure on carbon cloth substrate, then covalently immobilizing glucose oxidase on the dendritic gold, and then increasing enzyme loading by enzyme precipitation coating. The morphology of dendritic gold nanostructures was characterized by scanning electron microscopy (SEM). The electrochemical performance of the biosensor was analyzed by cyclic voltammetry (CV), chronoamperometry curve and electrochemical impedance spectroscopy (EIS). It is found that the obtained biosensor has high sensitivity (72.45 μA mM−1 cm−2), low detection limit (6.7 μM) and ultra-wide linear range (0.02–31.7 mM) for glucose detection. In addition, the biosensor also has good selectivity, reproducibility and stability. In the detection of real serum samples, the biosensor also shows good accuracy and practicality. The results show that the new biosensor has great potential for applications in biomedical and health care.
AB - With the development of blood glucose monitoring medical devices, higher requirements are put forward for the sensitivity and detection limit of biosensors. Herein, a high-performance flexible enzymatic glucose biosensor was prepared by electrochemical deposition of dendritic gold nanostructure on carbon cloth substrate, then covalently immobilizing glucose oxidase on the dendritic gold, and then increasing enzyme loading by enzyme precipitation coating. The morphology of dendritic gold nanostructures was characterized by scanning electron microscopy (SEM). The electrochemical performance of the biosensor was analyzed by cyclic voltammetry (CV), chronoamperometry curve and electrochemical impedance spectroscopy (EIS). It is found that the obtained biosensor has high sensitivity (72.45 μA mM−1 cm−2), low detection limit (6.7 μM) and ultra-wide linear range (0.02–31.7 mM) for glucose detection. In addition, the biosensor also has good selectivity, reproducibility and stability. In the detection of real serum samples, the biosensor also shows good accuracy and practicality. The results show that the new biosensor has great potential for applications in biomedical and health care.
KW - Biosensor
KW - Dendritic gold nanostructures
KW - Enzyme precipitation coating
KW - Glucose oxidase
UR - http://www.scopus.com/inward/record.url?scp=85138163457&partnerID=8YFLogxK
U2 - 10.1016/j.enzmictec.2022.110132
DO - 10.1016/j.enzmictec.2022.110132
M3 - 文章
C2 - 36152594
AN - SCOPUS:85138163457
SN - 0141-0229
VL - 162
JO - Enzyme and Microbial Technology
JF - Enzyme and Microbial Technology
M1 - 110132