Dynamic increase factor for progressive collapse of semi-rigid steel frames with extended endplate connection

Ying Huang, Yan Wu, Changhong Chen, Zhaohui Huang, Yao Yao

科研成果: 期刊稿件文章同行评审

7 引用 (Scopus)

摘要

As an extremely destructive accident, progressive collapse is defined as the spread of an initial local failure from element to element, resulting eventually in the collapse of an entire structure or disproportionately large of it. To prevent the occurrence of it and evaluate the ability of structure resisting progressive collapse, the nonlinear static procedure is usually adopted in the whole structure design process, which considered dynamic effect by utilizing Dynamic Increase Factor (DIF). In current researches, the determining of DIF is performed in full-rigid frame, however, the performance of beam-column connection in the majority of existing frame structures is not full-rigid. In this study, based on the component method proposed by EC3 guideline, the expression of extended endplate connection performance is further derived, and the connection performance is taken into consideration when evaluated the performance of structure resisting progressive collapse by applying the revised plastic P-M hinge. The DIF for structures with extended endplate beam-column connection have been determined and compared with the DIF permitted in current GSA guideline, the necessity of considering connection stiffness in determining the DIF have been proved.

源语言英语
页(从-至)617-628
页数12
期刊Steel and Composite Structures
31
6
DOI
出版状态已出版 - 2019

指纹

探究 'Dynamic increase factor for progressive collapse of semi-rigid steel frames with extended endplate connection' 的科研主题。它们共同构成独一无二的指纹。

引用此