TY - JOUR
T1 - Computational analysis of span-wise hole locations on fluid flow and film cooling of internal channels with crescent ribs
AU - Zhang, Guohua
AU - Liu, Xueting
AU - Sundén, Bengt Ake
AU - Xie, Gongnan
N1 - Publisher Copyright:
© 2019, Emerald Publishing Limited.
PY - 2019/9/11
Y1 - 2019/9/11
N2 - Purpose: This study aims to clarify the mechanism of film hole location at the span-wise direction of an internal cooling channel with crescent ribs on the adiabatic film cooling performance, three configurations are designed to observe the effects of the distance between the center of the ellipse and the side wall(Case 1, l = w/2, Case 2, l = w/3 and for Case 3, l = w/4). Design/methodology/approach: Numerical simulations are conducted under two blowing ratios (i.e. 0.5 and 1) and a fixed cross-flow Reynolds number (Rec = 100,000) with a verified turbulence model. Findings: It is shown that at low blowing ratio, reducing the distance increases the film cooling effectiveness but keeps the trend of the effectiveness unchanged, while at high blowing ratio, the characteristic is a little bit different in the range of 0 = x/D = 10. Research limitations/implications: These features could be explained by the fact that shrinking the distance between the hole and side wall induces a much smaller reserved region and vortex downstream the ribs and a lower resistance for cooling air entering the film hole. Furthermore, the spiral flow inside the hole is impaired. Originality/value: As a result, the kidney-shaped vortices originating from the jet flow are weakened, and the target surface can be well covered, resulting in an enhancement of the adiabatic film cooling performance.
AB - Purpose: This study aims to clarify the mechanism of film hole location at the span-wise direction of an internal cooling channel with crescent ribs on the adiabatic film cooling performance, three configurations are designed to observe the effects of the distance between the center of the ellipse and the side wall(Case 1, l = w/2, Case 2, l = w/3 and for Case 3, l = w/4). Design/methodology/approach: Numerical simulations are conducted under two blowing ratios (i.e. 0.5 and 1) and a fixed cross-flow Reynolds number (Rec = 100,000) with a verified turbulence model. Findings: It is shown that at low blowing ratio, reducing the distance increases the film cooling effectiveness but keeps the trend of the effectiveness unchanged, while at high blowing ratio, the characteristic is a little bit different in the range of 0 = x/D = 10. Research limitations/implications: These features could be explained by the fact that shrinking the distance between the hole and side wall induces a much smaller reserved region and vortex downstream the ribs and a lower resistance for cooling air entering the film hole. Furthermore, the spiral flow inside the hole is impaired. Originality/value: As a result, the kidney-shaped vortices originating from the jet flow are weakened, and the target surface can be well covered, resulting in an enhancement of the adiabatic film cooling performance.
KW - Blowing ratio
KW - Crescent rib
KW - Film cooling effectiveness
KW - Kidney-shaped vortices
KW - Spanwise distance
UR - http://www.scopus.com/inward/record.url?scp=85070413666&partnerID=8YFLogxK
U2 - 10.1108/HFF-09-2018-0474
DO - 10.1108/HFF-09-2018-0474
M3 - 文章
AN - SCOPUS:85070413666
SN - 0961-5539
VL - 29
SP - 2728
EP - 2753
JO - International Journal of Numerical Methods for Heat and Fluid Flow
JF - International Journal of Numerical Methods for Heat and Fluid Flow
IS - 8
ER -