Biotribology behavior of ultra-high molecular weight polyethylene against carbon/carbon composites used for hip joint replacement

Lei Lei Zhang, He Jun Li, Ke Zhi Li, Ling Jun Guo, Wei Feng Cao, Xue Tao Shen

科研成果: 书/报告/会议事项章节会议稿件同行评审

1 引用 (Scopus)

摘要

In order to investigate the biotribology behavior of a novel artificial joint pair composed of a carbon/carbon composite femoral head and an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup, a hip joint simulator was employed to predict the clinical wear behavior with a constant load and a lubricant of newborn calf serum. The worn surface and the wear particles generated were analyzed by scanning electron microscopy and laser particle size analyzer. The results showed that the worn surface of UHMWPE had a ripple-like morphology with plentiful furrows. The wear particles generated had various morphologies with a size concentrated at about 15 μm.

源语言英语
主期刊名Energy, Environment and Biological Materials
出版商Trans Tech Publications Ltd
327-330
页数4
ISBN(印刷版)9783037851159
DOI
出版状态已出版 - 2011

出版系列

姓名Materials Science Forum
685
ISSN(印刷版)0255-5476
ISSN(电子版)1662-9752