TY - JOUR
T1 - A micro-spectrometer with phase modulation array
AU - Yang, Tao
AU - Chen, Yuchao
AU - Li, Xing'ao
AU - Huang, Wei
AU - Zhu, Yongyuan
PY - 2014/3
Y1 - 2014/3
N2 - A micro-spectrometer with phase modulation array is investigated in this paper. The vital component of this micro-spectrometer is a micro-interferometer array, which is built on a charge-coupled device (CCD) or a complementary metal oxide semiconductor (CMOS). Each element of micro-interferometer array is formed by polymethyl methacrylate (PMMA) grooves with different depth. When we illuminate the surface of the interferometer array, different interference intensity distribution would be formed at the bottom of each micro-interferometer. Optical power of this interferometer can be measured by the pixels of CCD or CMOS. The data can be substituted into a linear system. By solving the linear system with Tikhonov regularization method, spectrum of the incident beam can be reconstructed. Simulation results prove that the detection range of the spectrometer is a wide wavelength range covering from 300 to 1100 nm. Furthermore, the wavelength resolution of the device reaches picometer level. In comparison with conventional spectrometers, the novel spectrometer has distinct advantages of small size, low cost, high resolution, wide spectral measurement range, real-time measurement, and so on.
AB - A micro-spectrometer with phase modulation array is investigated in this paper. The vital component of this micro-spectrometer is a micro-interferometer array, which is built on a charge-coupled device (CCD) or a complementary metal oxide semiconductor (CMOS). Each element of micro-interferometer array is formed by polymethyl methacrylate (PMMA) grooves with different depth. When we illuminate the surface of the interferometer array, different interference intensity distribution would be formed at the bottom of each micro-interferometer. Optical power of this interferometer can be measured by the pixels of CCD or CMOS. The data can be substituted into a linear system. By solving the linear system with Tikhonov regularization method, spectrum of the incident beam can be reconstructed. Simulation results prove that the detection range of the spectrometer is a wide wavelength range covering from 300 to 1100 nm. Furthermore, the wavelength resolution of the device reaches picometer level. In comparison with conventional spectrometers, the novel spectrometer has distinct advantages of small size, low cost, high resolution, wide spectral measurement range, real-time measurement, and so on.
KW - micro-spectrometer
KW - spectrum reconstruction
KW - Tikhonov regularization
UR - http://www.scopus.com/inward/record.url?scp=84895151811&partnerID=8YFLogxK
U2 - 10.1007/s12200-013-0363-5
DO - 10.1007/s12200-013-0363-5
M3 - 文章
AN - SCOPUS:84895151811
SN - 2095-2759
VL - 7
SP - 59
EP - 63
JO - Frontiers of Optoelectronics
JF - Frontiers of Optoelectronics
IS - 1
ER -