TY - JOUR
T1 - A high-temperature acoustic field measurement and analysis system for determining cavitation intensity in ultrasonically solidified metallic alloys
AU - Xu, Nanxuan
AU - Yu, Yang
AU - Zhai, Wei
AU - Wang, Jianyuan
AU - Wei, Bingbo
N1 - Publisher Copyright:
© 2023 The Authors
PY - 2023/3
Y1 - 2023/3
N2 - A high-temperature acoustic field measurement and analysis system (HTAFS) was self-designed and developed to achieve real-time acoustic field analysis and quantitative cavitation characterization within high-temperature liquids. The acoustic signal was acquired by a high-temperature resistant waveguide and calibrated by separate compensation of line and continuous spectra to eliminate frequency offsets. Moreover, a new method was proposed to derive from the continuous-spectrum sound intensity and line-spectrum sound intensity in the frequency band above 1.5 times the fundamental frequency to characterize the intensity of transient cavitation and stable cavitation. The acoustic field characteristics within solidifying liquid Al-7 %Si alloy were successfully determined by this system. With the increase of ultrasound amplitude, the acoustic pressure in the alloy melt increased to be stable, the transient cavitation intensity first rose and then declined, and the stable cavitation intensity remained unchanged. Combined with the structural evolution of the primary α(Al) phase, the transient cavitation intensity was determined to be the dominant factor for the ultrasound-induced grain refinement effect.
AB - A high-temperature acoustic field measurement and analysis system (HTAFS) was self-designed and developed to achieve real-time acoustic field analysis and quantitative cavitation characterization within high-temperature liquids. The acoustic signal was acquired by a high-temperature resistant waveguide and calibrated by separate compensation of line and continuous spectra to eliminate frequency offsets. Moreover, a new method was proposed to derive from the continuous-spectrum sound intensity and line-spectrum sound intensity in the frequency band above 1.5 times the fundamental frequency to characterize the intensity of transient cavitation and stable cavitation. The acoustic field characteristics within solidifying liquid Al-7 %Si alloy were successfully determined by this system. With the increase of ultrasound amplitude, the acoustic pressure in the alloy melt increased to be stable, the transient cavitation intensity first rose and then declined, and the stable cavitation intensity remained unchanged. Combined with the structural evolution of the primary α(Al) phase, the transient cavitation intensity was determined to be the dominant factor for the ultrasound-induced grain refinement effect.
KW - High-temperature acoustic field measurement
KW - Stable cavitation
KW - Transient cavitation
KW - Ultrasonic solidification
UR - http://www.scopus.com/inward/record.url?scp=85148956084&partnerID=8YFLogxK
U2 - 10.1016/j.ultsonch.2023.106343
DO - 10.1016/j.ultsonch.2023.106343
M3 - 文章
C2 - 36858007
AN - SCOPUS:85148956084
SN - 1350-4177
VL - 94
JO - Ultrasonics Sonochemistry
JF - Ultrasonics Sonochemistry
M1 - 106343
ER -