TY - JOUR
T1 - Validation of right coronary artery lumen area from cardiac computed tomography against intravascular ultrasound
AU - Cui, Hengfei
AU - Xia, Yong
AU - Zhang, Yanning
AU - Zhong, Liang
N1 - Publisher Copyright:
© 2018, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Quantification of coronary artery disease (CAD) from cardiac computed tomography angiography (CTA) is important both structurally (lumen area stenosis) and functionally (combined with computational fluid dynamics to determine fractional flow reserve) for assessment of ischemic stenosis and to guide treatment. Hence, it is important to have CTA image processing technique for segmentation and reconstruction of coronary arteries. In this study, we developed segmentation and reconstruction techniques, based on fast marching and Runge–Kutta methods for centerline extraction, and surface mesh generation. The accuracy of the reconstructed models was validated with direct intravascular ultrasound (IVUS) measurements in 1950 cross sections within 4 arteries. High correlation was found between CTA and IVUS measurements for lumen areas (r= 0.993 , p< 0.001). Receiver-operating characteristic (ROC) curves showed excellent accuracies for detection of different cutoff values of cross-lumen area (5 mm 2, 6 mm 2, 7 mm 2 and 8 mm 2, all ROC values >0.99). We conclude that our technique has sufficient accuracy for quantifying coronary lumen area. The accuracy and efficiency demonstrated that our approach can facilitate quantitative evaluation of coronary stenosis and potentially help in real-time assessment of CAD.
AB - Quantification of coronary artery disease (CAD) from cardiac computed tomography angiography (CTA) is important both structurally (lumen area stenosis) and functionally (combined with computational fluid dynamics to determine fractional flow reserve) for assessment of ischemic stenosis and to guide treatment. Hence, it is important to have CTA image processing technique for segmentation and reconstruction of coronary arteries. In this study, we developed segmentation and reconstruction techniques, based on fast marching and Runge–Kutta methods for centerline extraction, and surface mesh generation. The accuracy of the reconstructed models was validated with direct intravascular ultrasound (IVUS) measurements in 1950 cross sections within 4 arteries. High correlation was found between CTA and IVUS measurements for lumen areas (r= 0.993 , p< 0.001). Receiver-operating characteristic (ROC) curves showed excellent accuracies for detection of different cutoff values of cross-lumen area (5 mm 2, 6 mm 2, 7 mm 2 and 8 mm 2, all ROC values >0.99). We conclude that our technique has sufficient accuracy for quantifying coronary lumen area. The accuracy and efficiency demonstrated that our approach can facilitate quantitative evaluation of coronary stenosis and potentially help in real-time assessment of CAD.
KW - Centerline
KW - Coronary artery segmentation
KW - Lumen area
KW - Stenosis
UR - http://www.scopus.com/inward/record.url?scp=85054103873&partnerID=8YFLogxK
U2 - 10.1007/s00138-018-0978-z
DO - 10.1007/s00138-018-0978-z
M3 - 文章
AN - SCOPUS:85054103873
SN - 0932-8092
VL - 29
SP - 1287
EP - 1298
JO - Machine Vision and Applications
JF - Machine Vision and Applications
IS - 8
ER -