Abstract
We develop a transmission and total internal reflection (TIR) integrated digital holographic microscopy (DHM) by introducing a home-made Dove prism with a polished short side. With the help of angular and polarization multiplexing techniques, the 2D refractive index distribution of a specimen adhered on the prism surface is determined using TIR-DHM. Meanwhile, the thickness profile is unambiguously calculated from the phase information using transmission DHM. This integrated microscopy is nondestructive and dynamic and can be used to simultaneously measure the index distribution and thickness profile of transparent or semi-transparent liquid or solid samples.
Original language | English |
---|---|
Pages (from-to) | 3844-3847 |
Number of pages | 4 |
Journal | Optics Letters |
Volume | 41 |
Issue number | 16 |
DOIs | |
State | Published - 15 Aug 2016 |