TY - JOUR
T1 - Robust myoelectric pattern recognition methods for reducing users’ calibration burden
T2 - challenges and future
AU - Wang, Xiang
AU - Ao, Di
AU - Li, Le
N1 - Publisher Copyright:
Copyright © 2024 Wang, Ao and Li.
PY - 2024
Y1 - 2024
N2 - Myoelectric pattern recognition (MPR) has evolved into a sophisticated technology widely employed in controlling myoelectric interface (MI) devices like prosthetic and orthotic robots. Current MIs not only enable multi-degree-of-freedom control of prosthetic limbs but also demonstrate substantial potential in consumer electronics. However, the non-stationary random characteristics of myoelectric signals poses challenges, leading to performance degradation in practical scenarios such as electrode shifting and switching new users. Conventional MIs often necessitate meticulous calibration, imposing a significant burden on users. To address user frustration during the calibration process, researchers have focused on identifying MPR methods that alleviate this burden. This article categorizes common scenarios that incur calibration burdens as based on data distribution shift and based on dynamic data categories. Then further investigated and summarized the popular robust MPR algorithms used to reduce the user’s calibration burden. We categorize these algorithms as based on data manipulate, feature manipulation and, model structure. And describes the scenarios to which each method is applicable and the conditions required for calibration. Finally, this review is concluded with the advantages of robust MPR and the remaining challenges and future opportunities.
AB - Myoelectric pattern recognition (MPR) has evolved into a sophisticated technology widely employed in controlling myoelectric interface (MI) devices like prosthetic and orthotic robots. Current MIs not only enable multi-degree-of-freedom control of prosthetic limbs but also demonstrate substantial potential in consumer electronics. However, the non-stationary random characteristics of myoelectric signals poses challenges, leading to performance degradation in practical scenarios such as electrode shifting and switching new users. Conventional MIs often necessitate meticulous calibration, imposing a significant burden on users. To address user frustration during the calibration process, researchers have focused on identifying MPR methods that alleviate this burden. This article categorizes common scenarios that incur calibration burdens as based on data distribution shift and based on dynamic data categories. Then further investigated and summarized the popular robust MPR algorithms used to reduce the user’s calibration burden. We categorize these algorithms as based on data manipulate, feature manipulation and, model structure. And describes the scenarios to which each method is applicable and the conditions required for calibration. Finally, this review is concluded with the advantages of robust MPR and the remaining challenges and future opportunities.
KW - cross-scenario
KW - cross-subject
KW - electrode shift
KW - electromyography (EMG)
KW - HD-sEMG
KW - myoelectric pattern recognition (MPR)
KW - robust myoelectric control
UR - http://www.scopus.com/inward/record.url?scp=85184243945&partnerID=8YFLogxK
U2 - 10.3389/fbioe.2024.1329209
DO - 10.3389/fbioe.2024.1329209
M3 - 文献综述
AN - SCOPUS:85184243945
SN - 2296-4185
VL - 12
JO - Frontiers in Bioengineering and Biotechnology
JF - Frontiers in Bioengineering and Biotechnology
M1 - 1329209
ER -