TY - JOUR
T1 - Non-axisymmetric Endwall film cooling characteristics considering the influences of cylindrical holes and laidback fan-shaped holes
AU - Du, Kun
AU - Jia, Yihao
AU - Liu, Cunliang
AU - Sunden, Bengt
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/6/15
Y1 - 2024/6/15
N2 - Flow fields near the turbine vane endwall are complicated due to the endwall cross flows. The use of a non-axisymmetric endwall is regarded as an efficient technique to reduce the lateral pressure difference, decreasing the endwall cross flow. Numerical analysis was performed to determine how the non-axisymmetric endwall affected the vortex structure and heat transfer level. The cooling performance was investigated with cylindrical and laidback fan-shaped holes (7–7–7), which were arranged in rows aligned in the axial direction. The results showed that the non-axisymmetric endwall could significantly reduce the circumferential pressure difference and suppress the growth of the passage vortex, and the area-averaged heat transfer coefficient was reduced by 3.34%. The outlet area of the film hole was altered by the non-axisymmetric endwall, and the over-cooled regions may have appeared as a result of the excessive area increase. The influence of the non-axisymmetric endwall was concentrated at 0.4 < Z/Cax < 1.0 for the cylindrical hole. With the increase in M, the film cooling effectiveness of the non-axisymmetric endwall attained a higher level than that of the flat endwall. For the laidback fan-shaped hole, the effect of the non-axisymmetric endwall was confined within 0.25 < Z/Cax < 1.0. The half-period trigonometric function of the non-axisymmetric endwall (HTFN) achieved the optimal cooling performance for three blowing ratios. However, the periodic trigonometric function of the non-axisymmetric endwall (PTFN) only outperformed the flat endwall when M= 1.5.
AB - Flow fields near the turbine vane endwall are complicated due to the endwall cross flows. The use of a non-axisymmetric endwall is regarded as an efficient technique to reduce the lateral pressure difference, decreasing the endwall cross flow. Numerical analysis was performed to determine how the non-axisymmetric endwall affected the vortex structure and heat transfer level. The cooling performance was investigated with cylindrical and laidback fan-shaped holes (7–7–7), which were arranged in rows aligned in the axial direction. The results showed that the non-axisymmetric endwall could significantly reduce the circumferential pressure difference and suppress the growth of the passage vortex, and the area-averaged heat transfer coefficient was reduced by 3.34%. The outlet area of the film hole was altered by the non-axisymmetric endwall, and the over-cooled regions may have appeared as a result of the excessive area increase. The influence of the non-axisymmetric endwall was concentrated at 0.4 < Z/Cax < 1.0 for the cylindrical hole. With the increase in M, the film cooling effectiveness of the non-axisymmetric endwall attained a higher level than that of the flat endwall. For the laidback fan-shaped hole, the effect of the non-axisymmetric endwall was confined within 0.25 < Z/Cax < 1.0. The half-period trigonometric function of the non-axisymmetric endwall (HTFN) achieved the optimal cooling performance for three blowing ratios. However, the periodic trigonometric function of the non-axisymmetric endwall (PTFN) only outperformed the flat endwall when M= 1.5.
KW - Aerodynamic characteristics
KW - Film cooling
KW - Laidback Fan-shaped Hole
KW - Non-axisymmetric endwall
UR - http://www.scopus.com/inward/record.url?scp=85188026662&partnerID=8YFLogxK
U2 - 10.1016/j.ijheatmasstransfer.2024.125403
DO - 10.1016/j.ijheatmasstransfer.2024.125403
M3 - 文章
AN - SCOPUS:85188026662
SN - 0017-9310
VL - 225
JO - International Journal of Heat and Mass Transfer
JF - International Journal of Heat and Mass Transfer
M1 - 125403
ER -