MTPA Control of Wound-Rotor Synchronous Start/Generator Drives Based on Virtual Signal Injection Considering Cross-Coupling Effect in Low-Speed Range

Research output: Contribution to journalArticlepeer-review

Abstract

The cross-coupling effect is the most common phenomenon in the electric machinery operation. It has the influence on the machine efficiency and control scheme. However, the cross-coupling effect is ignored in the existing virtual signal injection (VSI) maximum torque per ampere (MTPA) control. In this article, the online searching MTPA control based on the VSI scheme for integrated starter/generator system considering the cross-coupling effect is proposed. For obtaining the accurate torque gradient with respect to the torque angle online, the torque equations in the existing VSI schemes are extended by the cross-coupling effect and the influence of the iron loss and temperature rise is studied. In this article, the partial parameters method is proposed. A prototype is set up, and the experiments are carried out to verify the effectiveness of the proposed control scheme.

Original languageEnglish
Pages (from-to)6115-6124
Number of pages10
JournalIEEE Transactions on Power Electronics
Volume39
Issue number5
DOIs
StatePublished - 1 May 2024

Keywords

  • Cross-coupling effect
  • maximum torque per ampere (MTPA)
  • online searching

Fingerprint

Dive into the research topics of 'MTPA Control of Wound-Rotor Synchronous Start/Generator Drives Based on Virtual Signal Injection Considering Cross-Coupling Effect in Low-Speed Range'. Together they form a unique fingerprint.