Is maximum isometric muscle stress the same among prime elbow flexors?

Le Li, Kaiyu Tong, Rong Song, Terry K.K. Koo

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Background: Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods: Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings: Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation: Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions.

Original languageEnglish
Pages (from-to)874-883
Number of pages10
JournalClinical Biomechanics
Volume22
Issue number8
DOIs
StatePublished - Oct 2007
Externally publishedYes

Keywords

  • Elbow
  • Maximum isometric muscle stress
  • Musculoskeletal model
  • Musculotendon parameters
  • Ultrasonography

Fingerprint

Dive into the research topics of 'Is maximum isometric muscle stress the same among prime elbow flexors?'. Together they form a unique fingerprint.

Cite this