TY - JOUR
T1 - Iron Oxide Nanoparticle-Powered Micro-Optical Coherence Tomography for in Situ Imaging the Penetration and Swelling of Polymeric Microneedles in the Skin
AU - Seeni, Razina Z.
AU - Yu, Xiaojun
AU - Chang, Hao
AU - Chen, Peng
AU - Liu, Linbo
AU - Xu, Chenjie
N1 - Publisher Copyright:
© 2017 American Chemical Society.
PY - 2017/6/21
Y1 - 2017/6/21
N2 - In recent years, polymeric microneedles (MNs) have attracted keen interests among researchers because of their applicability in transdermal drug delivery and interstitial skin fluid (ISF) extraction. When designing and characterizing such devices, it is critical to monitor their real-time in vitro and in vivo performances to optimize the desired effects, yet most of the existing methods are incapable of such functions. To address this unmet need, we develop a real-time noninvasive imaging methodology by integrating iron oxide (Fe3O4) nanoparticles into polymeric MNs to enhance image contrast for micro-optical coherence tomography (μOCT) imaging. Using the Fe3O4-integrated polystyrene-block-poly(acrylic acid) (PS-b-PAA) MNs as an example, we evaluate the influences of Fe3O4 concentrations on contrast enhancement in μOCT imaging and visualize the real-time swelling process of polymeric MNs in biological samples for the first time. Our results show that a concentration of â4-5 wt % Fe3O4 nanoparticles not only helps achieve the best contrast-to-noise ratio in μOCT imaging, which is 10 times higher than that without Fe3O4 nanoparticles in air and hydrogel, but also enables the real-time changes in the profile of MNs to be observed clearly in their swelling process in skin tissues. On the basis of such findings, we utilize the optimized concentration of Fe3O4 nanoparticles to further quantitatively study the swelling kinetics of PS-b-PAA MNs in agarose hydrogel and fresh skin tissues, which lasts â20 and â30-35 s, respectively. The suitability of such a methodology for enhancing μOCT imaging would greatly facilitate the development and clinical translation of MN-based medical technologies.
AB - In recent years, polymeric microneedles (MNs) have attracted keen interests among researchers because of their applicability in transdermal drug delivery and interstitial skin fluid (ISF) extraction. When designing and characterizing such devices, it is critical to monitor their real-time in vitro and in vivo performances to optimize the desired effects, yet most of the existing methods are incapable of such functions. To address this unmet need, we develop a real-time noninvasive imaging methodology by integrating iron oxide (Fe3O4) nanoparticles into polymeric MNs to enhance image contrast for micro-optical coherence tomography (μOCT) imaging. Using the Fe3O4-integrated polystyrene-block-poly(acrylic acid) (PS-b-PAA) MNs as an example, we evaluate the influences of Fe3O4 concentrations on contrast enhancement in μOCT imaging and visualize the real-time swelling process of polymeric MNs in biological samples for the first time. Our results show that a concentration of â4-5 wt % Fe3O4 nanoparticles not only helps achieve the best contrast-to-noise ratio in μOCT imaging, which is 10 times higher than that without Fe3O4 nanoparticles in air and hydrogel, but also enables the real-time changes in the profile of MNs to be observed clearly in their swelling process in skin tissues. On the basis of such findings, we utilize the optimized concentration of Fe3O4 nanoparticles to further quantitatively study the swelling kinetics of PS-b-PAA MNs in agarose hydrogel and fresh skin tissues, which lasts â20 and â30-35 s, respectively. The suitability of such a methodology for enhancing μOCT imaging would greatly facilitate the development and clinical translation of MN-based medical technologies.
KW - contrast agent
KW - imaging
KW - interstitial fluid extraction
KW - iron oxide nanoparticles
KW - microneedles
KW - optical coherence tomography
UR - http://www.scopus.com/inward/record.url?scp=85021154954&partnerID=8YFLogxK
U2 - 10.1021/acsami.7b00481
DO - 10.1021/acsami.7b00481
M3 - 文章
C2 - 28530093
AN - SCOPUS:85021154954
SN - 1944-8244
VL - 9
SP - 20340
EP - 20347
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 24
ER -