Investigation of fretting fatigue behavior of Ti811 alloy at elevated temperature

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

The fretting fatigue behavior of the Ti811titanium alloy, as influenced by temperature, slip amplitude, and contact pressure, was investigated using a high-frequency fatigue machine and a home-made high-temperature apparatus. The fretting fatigue failure mechanisms were studied by observing the fretting surface morphology features. The results show that the sensitivity to fretting fatigue is high at both 350°C and 500°C. The higher the temperature is, the more sensitive the alloy is to fretting fatigue failure. Creep is an important factor that influences the fretting fatigue failure process at elevated temperature. The fretting fatigue life of the Ti811 alloy does not change in a monotonic way as the slip amplitude and contact pressure increase. This is due to the fact that the slip amplitude affects the action of fatigue and wear in the fretting process, and the nominal contact pressure affects the distribution and concentration of the stress and the amplitude of fretting slip at the contact surface, and thus further influences the crack initiation probability and the driving force for propagation.

Original languageEnglish
Pages (from-to)5489-5494
Number of pages6
JournalInternational Journal of Modern Physics B
Volume22
Issue number31-32
DOIs
StatePublished - 30 Dec 2008

Keywords

  • Creep
  • Elevated temperature
  • Fretting fatigue
  • Titanium alloy
  • Wear

Fingerprint

Dive into the research topics of 'Investigation of fretting fatigue behavior of Ti811 alloy at elevated temperature'. Together they form a unique fingerprint.

Cite this