Abstract
An improved multi-step sintering process was used to in-situ prepare TiB2-TiB-Ti FGMs. According to the sintering temperatures, the functionally graded materials (FGMs) were divided into three sections. After sintering at a proper temperature, the three sections were sintered together in turn. The experimental results showed that there were no obvious pores and cracks in the whole TiB2-TiB-Ti FGMs, and no delamination was found in the impacting test with good performance features, which indicated that there were no interface effects in FGMs during penetration, so that the TiB2-TiB-Ti FGMs were an ideal FGM.
Original language | English |
---|---|
Pages (from-to) | 710-714 |
Number of pages | 5 |
Journal | Journal Wuhan University of Technology, Materials Science Edition |
Volume | 30 |
Issue number | 4 |
DOIs | |
State | Published - 30 Aug 2015 |
Keywords
- Fabrication
- FGMs
- Ti
- TiB