TY - JOUR
T1 - Heterogeneous, 3D Architecturing of 2D Titanium Carbide (MXene) for Microdroplet Manipulation and Voice Recognition
AU - Zhang, Ye
AU - Chang, Ting Hsiang
AU - Jing, Lin
AU - Li, Kerui
AU - Yang, Haitao
AU - Chen, Po Yen
N1 - Publisher Copyright:
Copyright © 2020 American Chemical Society.
PY - 2020/2/19
Y1 - 2020/2/19
N2 - Mismatched deformation in a bilayer composite with rigid coating on a soft substrate results in complex and uniform topographic patterns, yet it remains challenging to heterogeneously pattern the upper coatings with various localized structures. Herein, a heterogeneous, 3D microstructure composed of Ti3C2Tx titanium carbide (MXene) and single-walled carbon nanotubes (SWNTs) was fabricated using a one-step deformation of a thermally responsive substrate with designed open holes. The mechanically deformed SWNT-MXene (s-MXene) structure was next transferred onto an elastomeric substrate, and the resulting s-MXene/elastomer bilayer device exhibited three localized surface patterns, including isotropic crumples, periodic wrinkles, and large papillae-like microstructures. By adjusting the number and pattern, the s-MXene papillae arrays exhibited superhydrophobicity (>170°), strong and tunable adhesive force (52.3-110.6 μN), and ultra-large liquid capacity (up to 35 μL) for programmable microdroplet manipulation. The electrically conductive nature of s-MXene further enabled proper thermal management on microdroplets via Joule heating for miniaturized antibacterial tests. The s-MXene papillae were further fabricated in a piezoresistive pressure sensor with high sensitivity (11.47 kPa-1). The output current changes of s-MXene sensors were highly sensitive to voice vibrations and responded identically with prerecorded profiles, promising their application in accurate voice acquisition and recognition.
AB - Mismatched deformation in a bilayer composite with rigid coating on a soft substrate results in complex and uniform topographic patterns, yet it remains challenging to heterogeneously pattern the upper coatings with various localized structures. Herein, a heterogeneous, 3D microstructure composed of Ti3C2Tx titanium carbide (MXene) and single-walled carbon nanotubes (SWNTs) was fabricated using a one-step deformation of a thermally responsive substrate with designed open holes. The mechanically deformed SWNT-MXene (s-MXene) structure was next transferred onto an elastomeric substrate, and the resulting s-MXene/elastomer bilayer device exhibited three localized surface patterns, including isotropic crumples, periodic wrinkles, and large papillae-like microstructures. By adjusting the number and pattern, the s-MXene papillae arrays exhibited superhydrophobicity (>170°), strong and tunable adhesive force (52.3-110.6 μN), and ultra-large liquid capacity (up to 35 μL) for programmable microdroplet manipulation. The electrically conductive nature of s-MXene further enabled proper thermal management on microdroplets via Joule heating for miniaturized antibacterial tests. The s-MXene papillae were further fabricated in a piezoresistive pressure sensor with high sensitivity (11.47 kPa-1). The output current changes of s-MXene sensors were highly sensitive to voice vibrations and responded identically with prerecorded profiles, promising their application in accurate voice acquisition and recognition.
KW - 2D titanium carbide (MXene)
KW - crumpled and wrinkled structures
KW - flexible pressure sensor
KW - mechanical deformation
KW - microdroplet manipulation
KW - voice recognition
UR - http://www.scopus.com/inward/record.url?scp=85080065755&partnerID=8YFLogxK
U2 - 10.1021/acsami.9b18879
DO - 10.1021/acsami.9b18879
M3 - 文章
C2 - 31971769
AN - SCOPUS:85080065755
SN - 1944-8244
VL - 12
SP - 8392
EP - 8402
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 7
ER -