Experimental study on the wall temperature and heat transfer of a two-phase pulse detonation rocket engine

Yongjia Wang, Ke Wang, Wei Fan, Jiannan He, Yang Zhang, Qibin Zhang, Kuiguang Yao

Research output: Contribution to journalArticlepeer-review

29 Scopus citations

Abstract

An experimental work was conducted to study the wall temperature and heat transfer on a two-phase pulse detonation rocket engine. Three pressure transducers were employed to validate the fully developed detonation wave in the tube, while six thermocouples were used to measure the increasing temperature of the tube wall and calculate the heat load. The heat flux on the deflagration-to-detonation transition (DDT) section could be in the order of megawatt per square meter, which was 1.27–2.81 times that of the propagation section. The effects of operating conditions, such as the operating frequency and the equivalence ratio, on the heat load were also investigated. A positive correlation was observed between the heat load on the tube wall and the operating frequency, but the increasing trend would slow down gradually with the operating frequency. In addition, as the equivalence ratio increased, the heat load increased initially and decreased afterwards. It is suggested that the fuel-rich conditions should be avoided considering fuel wasting and tube wall over-heating. Moreover, heat transfer enhancement and heat-insulating coating should also be used to sufficiently cool down the engine, especially the DDT section.

Original languageEnglish
Pages (from-to)387-393
Number of pages7
JournalApplied Thermal Engineering
Volume114
DOIs
StatePublished - 5 Mar 2017

Keywords

  • Equivalence ratio
  • Frequency
  • Heat load
  • Regenerative cooling
  • Two-phase detonation

Fingerprint

Dive into the research topics of 'Experimental study on the wall temperature and heat transfer of a two-phase pulse detonation rocket engine'. Together they form a unique fingerprint.

Cite this