Experimental study on the influence of diffuser and inlet guide vane for the performance of centrifugal compressor

L. Zhou, Y. Xi, Y. Cai

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

An experimental study was conducted to investigate the performance of the centrifugal compressor under different diffuser stagger angles and different inlet guide vane (IGV) prewhirl angles in order to find the way of the optimum matched means of the IGV and vaned diffuser. In this experiment, it is found that the performance can be altered largely by adjusting the IGV prewhirl angles and diffuser stagger angles. In addition, the performance is quite sensitive to the negative prewhirl angle and small positive prewhirl angle of IGV when the diffuser stagger angle is reduced to its minimum value. Moreover, the maximum efficiency with simultaneous adjustment of the IGV prewhirl angle and the diffuser stagger angle can achieve. Furthermore, the optimum match between the IGV prewhirl angle and the diffuser stagger angle is a function of flow rate and the pressure ratio.

Original languageEnglish
Pages (from-to)26-33
Number of pages8
JournalExperimental Techniques
Volume32
Issue number5
DOIs
StatePublished - 2008

Fingerprint

Dive into the research topics of 'Experimental study on the influence of diffuser and inlet guide vane for the performance of centrifugal compressor'. Together they form a unique fingerprint.

Cite this