@inproceedings{fc1f382b267643c2a5010e5a337fee89,
title = "Effects of cooling air on performance of turbine blade based on CHT simulation",
abstract = "A numerical model for conjugate heat transfer (CHT) simulation is established for a turbine blade with air cooling, and 3D heat transfer simulation is accomplished.Effects of different amount of cooling air on the surface temperature distribution, work, efficiency of turbine blade is studied. The results show that the surface temperature drops quickly with the increase of cooling air at beginning and then become mild, the blade work goes up,the efficiency goes down.",
keywords = "Blade work, Conjugate heat transfer, Cooling air, Efficiency, Surface temperature, Turbine blade",
author = "Jing Li and Zhenxia Liu and Zhong Ren",
year = "2012",
doi = "10.4028/www.scientific.net/AMM.184-185.184",
language = "英语",
isbn = "9783037854419",
series = "Applied Mechanics and Materials",
pages = "184--187",
booktitle = "Frontiers of Mechanical Engineering and Materials Engineering",
note = "2012 International Conference on Frontiers of Mechanical Engineering and Materials Engineering, MEME 2012 ; Conference date: 27-07-2012 Through 29-07-2012",
}