Effect of temperature gradient on the ablation and flexural behavior of C/C-ZrC composites

Tianyu Liu, Qiangang Fu, Bing Liu, Jiaping Zhang

Research output: Contribution to journalArticlepeer-review

32 Scopus citations

Abstract

A new ablation condition was designed to investigate the effect of temperature gradient on the ablation and flexural behavior of the C/C-ZrC composites. The sample not only suffers the gradient temperature ablation ranging from 1000 to 2000 ℃ but withstands flexural load caused by the high-speed airflow scouring. The volume ablation rate of the C/C-ZrC was 0.06 mm3/s, which was only 6.81 % of the rate of the C/C. The volume change caused by ZrC→ZrO2 together with the ZrO2 crystalline transformation was beneficial for releasing internal stress, thereby contributing to the higher flexural strength retention of the C/C-ZrC composites.

Original languageEnglish
Article number109736
JournalCorrosion Science
Volume191
DOIs
StatePublished - Oct 2021

Keywords

  • C/C-ZrC composites
  • Flexural strength
  • Gradient ablation

Fingerprint

Dive into the research topics of 'Effect of temperature gradient on the ablation and flexural behavior of C/C-ZrC composites'. Together they form a unique fingerprint.

Cite this