T1 - Development of a paper-based method to detect Hg2+ in waste water using iturin from Bacillus subtilis
AU - Zhao, Xixi
AU - Ai, Chongyang
AU - Li, Zhenzhu
AU - Xu, Xiaoguang
AU - Zhao, Haobin
AU - Yan, Lu
AU - Jiang, Chunmei
AU - Shao, Dongyan
AU - Shi, Junling
N1 - Publisher Copyright:
© 2019, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2019/10/1
Y1 - 2019/10/1
N2 - Colorimetric, fluorescence, and paper-based method were developed to measure the Hg2+ level in water using iturin A, a lipopeptide produced by Bacillus subtilis. Firstly, iturin was used to synthesize highly stable and uniformly sized silver nanoparticles (AgNPs). Secondly, the iturin-AgNPs were found to be highly selective and sensitive to Hg2+. The absorbance of the reaction system showed a good linear correlation with the Hg2+ concentration from 0.5 to 5 mg/L at 450 nm in the UV-Vis spectroscopy detection with the limit of detection (LOD) of 0.5 mg/L. When the reaction system was detected by fluorescence measurement, a good linear relationship was found between the fluorescence intensity and Hg2+ concentration from 0.05 to 0.5 mg/ at 415 nm with the LOD of 0.05 mg/L. Lastly, a paper-based detection method was developed. The developed method was successfully used to detect Hg2+ in contaminated polluted waters and showed acceptable results in terms of sensitivity, selectivity and stability. The paper-based method could distinguish Hg2+ at levels higher than 0.05 mg/L, thereby meeting the guidelines of the effluent quality standard for industries (0.05 mg/L). In summary, this method can be used daily by various industries to monitor the Hg2+ level in effluent water.
AB - Colorimetric, fluorescence, and paper-based method were developed to measure the Hg2+ level in water using iturin A, a lipopeptide produced by Bacillus subtilis. Firstly, iturin was used to synthesize highly stable and uniformly sized silver nanoparticles (AgNPs). Secondly, the iturin-AgNPs were found to be highly selective and sensitive to Hg2+. The absorbance of the reaction system showed a good linear correlation with the Hg2+ concentration from 0.5 to 5 mg/L at 450 nm in the UV-Vis spectroscopy detection with the limit of detection (LOD) of 0.5 mg/L. When the reaction system was detected by fluorescence measurement, a good linear relationship was found between the fluorescence intensity and Hg2+ concentration from 0.05 to 0.5 mg/ at 415 nm with the LOD of 0.05 mg/L. Lastly, a paper-based detection method was developed. The developed method was successfully used to detect Hg2+ in contaminated polluted waters and showed acceptable results in terms of sensitivity, selectivity and stability. The paper-based method could distinguish Hg2+ at levels higher than 0.05 mg/L, thereby meeting the guidelines of the effluent quality standard for industries (0.05 mg/L). In summary, this method can be used daily by various industries to monitor the Hg2+ level in effluent water.
KW - Biological synthesis
KW - Fluorescence spectrophotometry
KW - Mercury ion
KW - Silver nanoparticle
KW - Test paper
KW - UV-visible spectrophotometry
UR - http://www.scopus.com/inward/record.url?scp=85073584050&partnerID=8YFLogxK
U2 - 10.1007/s00253-019-10109-5
DO - 10.1007/s00253-019-10109-5
M3 - 文章
C2 - 31522284
AN - SCOPUS:85073584050
SN - 0175-7598
VL - 103
SP - 8609
EP - 8618
JO - Applied Microbiology and Biotechnology
JF - Applied Microbiology and Biotechnology
IS - 20
ER -