An Experimental Study on the Effects of a Film Cooling Configuration and Mainstream Temperature on Depositing

Zhengang Liu, Zhenxia Liu, Fei Zhang, Yanan Liu

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

The effects of a film cooling configuration and mainstream temperature on the depositing of particles are experimentally studied by using plate models. The particles are generated by melting wax and atomizing it. One model has a film cooling configuration and the other does not. The experimental results show that the film cooling configuration does not influence the depositing on the leading edge of the model very significantly. However, the film cooling configuration could increase the depositing on the upper surface of the model dramatically since the flow structure on the upper surface is changed due to the film cooling configuration. The effect of the mainstream temperature on the depositing is studied by using the model with film cooling configuration. The lower and higher mainstream temperature both could reduce the depositing. However, the mechanisms are different. The lower mainstream temperature could make more molten particles become solid particles, which could rebound from the surface of the model, reducing the depositing. The higher mainstream temperature could make all particles remain molten with higher temperature. In this case, more particles could splash from the surface of the model. Therefore, there may be a mainstream temperature at which the depositing mass is maximum.

Original languageEnglish
Pages (from-to)360-369
Number of pages10
JournalJournal of Thermal Science
Volume28
Issue number2
DOIs
StatePublished - 1 Apr 2018

Keywords

  • depositing
  • dilute multiphase flow
  • film cooling

Fingerprint

Dive into the research topics of 'An Experimental Study on the Effects of a Film Cooling Configuration and Mainstream Temperature on Depositing'. Together they form a unique fingerprint.

Cite this