TY - JOUR
T1 - A Numerical Investigation of Film Cooling under the Effects of Different Adverse Pressure Gradients
AU - Shi, Jingwei
AU - Hui, Zhonghao
AU - Zhou, Li
AU - Wang, Zhanxue
AU - Liu, Yongquan
N1 - Publisher Copyright:
© 2024 by the authors.
PY - 2024/5
Y1 - 2024/5
N2 - Film cooling needs to be applied to serpentine nozzles due to an increase in thermal load. Adverse pressure gradients (APGs) near the upper wall of such nozzles hinder the forward flow of the coolant, and they may even induce a recirculation zone that complicates the cooling of the film in serpentine nozzles under different APGs. In this study, the film cooling characteristics of a serpentine nozzle under various APGs are investigated through numerical simulations. The studied pressure gradients include strong, moderate, and weak APGs. The results show that the APG weakened the adhesion of the coolant to the surface, thereby reducing the film cooling effectiveness (FCE) and the convective heat transfer coefficient (CHTC). The stronger the APG, the greater its obstructive effect. However, the recirculation zone induced by the strong APG was composed of the coolant, and it adhered tightly to the wall, thereby significantly strengthening the FCE and CHTC. The CHTC under the moderate APG significantly increased due to the convergence of two jets ejected from different holes. For the four blowing ratios, the area-averaged FCE under the strong APG was 29.8% and 24.5% higher than that under the moderate and weak APGs, while the area-averaged ratios of the CHTC under the moderate APG were 1.6% and 16.7% higher than those under the strong and weak APGs. Therefore, more holes should be arranged on the film in the zones of moderate and weak APGs.
AB - Film cooling needs to be applied to serpentine nozzles due to an increase in thermal load. Adverse pressure gradients (APGs) near the upper wall of such nozzles hinder the forward flow of the coolant, and they may even induce a recirculation zone that complicates the cooling of the film in serpentine nozzles under different APGs. In this study, the film cooling characteristics of a serpentine nozzle under various APGs are investigated through numerical simulations. The studied pressure gradients include strong, moderate, and weak APGs. The results show that the APG weakened the adhesion of the coolant to the surface, thereby reducing the film cooling effectiveness (FCE) and the convective heat transfer coefficient (CHTC). The stronger the APG, the greater its obstructive effect. However, the recirculation zone induced by the strong APG was composed of the coolant, and it adhered tightly to the wall, thereby significantly strengthening the FCE and CHTC. The CHTC under the moderate APG significantly increased due to the convergence of two jets ejected from different holes. For the four blowing ratios, the area-averaged FCE under the strong APG was 29.8% and 24.5% higher than that under the moderate and weak APGs, while the area-averaged ratios of the CHTC under the moderate APG were 1.6% and 16.7% higher than those under the strong and weak APGs. Therefore, more holes should be arranged on the film in the zones of moderate and weak APGs.
KW - adverse pressure gradient
KW - blowing ratio
KW - film cooling
KW - flow characteristics
KW - numerical investigation
UR - http://www.scopus.com/inward/record.url?scp=85194047549&partnerID=8YFLogxK
U2 - 10.3390/aerospace11050365
DO - 10.3390/aerospace11050365
M3 - 文章
AN - SCOPUS:85194047549
SN - 2226-4310
VL - 11
JO - Aerospace
JF - Aerospace
IS - 5
M1 - 365
ER -