N2 - Tissue stiffness is generally known to be associated with pathologic changes. Ultrasound indentation is able to assess the mechanical properties of soft tissues. Conventional ultrasound indentation devices use rigid flatended transducers to directly contact with the tissues and typically operate in the frequency ranging between 2 M Hz and 10 MHz. This paper introduced a novel ultrasound indentation system using water jet compression. The water jet served as an indenter as well as a medium for the propagation of the ultrasound beam. High frequency focused transducer was used to measure the indentation deformation at a microscopic level. It has been demonstrated that the system could effectively assess the tissue-mimicking phantoms with different stiffness. Moreover, another advantage of this novel indentation system was to apply C-scan on soft tissues rapidly and conveniently. By applying different pressures on C-scan sequences, the modulus image of the tissue could be obtained. This paper presented the preliminary results on gel phantoms. The spatial resolution and the sensitivity of the measurements, the reproducibility of the results were also discussed.
AB - Tissue stiffness is generally known to be associated with pathologic changes. Ultrasound indentation is able to assess the mechanical properties of soft tissues. Conventional ultrasound indentation devices use rigid flatended transducers to directly contact with the tissues and typically operate in the frequency ranging between 2 M Hz and 10 MHz. This paper introduced a novel ultrasound indentation system using water jet compression. The water jet served as an indenter as well as a medium for the propagation of the ultrasound beam. High frequency focused transducer was used to measure the indentation deformation at a microscopic level. It has been demonstrated that the system could effectively assess the tissue-mimicking phantoms with different stiffness. Moreover, another advantage of this novel indentation system was to apply C-scan on soft tissues rapidly and conveniently. By applying different pressures on C-scan sequences, the modulus image of the tissue could be obtained. This paper presented the preliminary results on gel phantoms. The spatial resolution and the sensitivity of the measurements, the reproducibility of the results were also discussed.
UR - http://www.scopus.com/inward/record.url?scp=33846915732&partnerID=8YFLogxK
M3 - 会议稿件
AN - SCOPUS:33846915732
SN - 0780387406
SN - 9780780387409
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 993
EP - 995
BT - Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
T2 - 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
Y2 - 1 September 2005 through 4 September 2005
ER -