跳到主要导航 跳到搜索 跳到主要内容

Viral Pneumonia Screening on Chest X-Rays Using Confidence-Aware Anomaly Detection

  • Jianpeng Zhang
  • , Yutong Xie
  • , Guansong Pang
  • , Zhibin Liao
  • , Johan Verjans
  • , Wenxing Li
  • , Zongji Sun
  • , Jian He
  • , Yi Li
  • , Chunhua Shen
  • , Yong Xia
  • Northwestern Polytechnical University Xian
  • Adelaide University
  • Jf Healthcare Inc
  • Nanjing University
  • GreyBird Ventures

科研成果: 期刊稿件 › 文章 › 同行评审

308 引用 (Scopus)

摘要

Clusters of viral pneumonia occurrences over a short period may be a harbinger of an outbreak or pandemic. Rapid and accurate detection of viral pneumonia using chest X-rays can be of significant value for large-scale screening and epidemic prevention, particularly when other more sophisticated imaging modalities are not readily accessible. However, the emergence of novel mutated viruses causes a substantial dataset shift, which can greatly limit the performance of classification-based approaches. In this paper, we formulate the task of differentiating viral pneumonia from non-viral pneumonia and healthy controls into a one-class classification-based anomaly detection problem. We therefore propose the confidence-Aware anomaly detection (CAAD) model, which consists of a shared feature extractor, an anomaly detection module, and a confidence prediction module. If the anomaly score produced by the anomaly detection module is large enough, or the confidence score estimated by the confidence prediction module is small enough, the input will be accepted as an anomaly case (i.e., viral pneumonia). The major advantage of our approach over binary classification is that we avoid modeling individual viral pneumonia classes explicitly and treat all known viral pneumonia cases as anomalies to improve the one-class model. The proposed model outperforms binary classification models on the clinical X-VIRAL dataset that contains 5,977 viral pneumonia (no COVID-19) cases, 37,393 non-viral pneumonia or healthy cases. Moreover, when directly testing on the X-COVID dataset that contains 106 COVID-19 cases and 107 normal controls without any fine-Tuning, our model achieves an AUC of 83.61% and sensitivity of 71.70%, which is comparable to the performance of radiologists reported in the literature.

源语言英语
期刊论文编号9272749
页(从-至)879-890
页数12
期刊IEEE Transactions on Medical Imaging
卷40
期3
DOI
出版状态已出版 - 3月 2021

学术指纹

探究 'Viral Pneumonia Screening on Chest X-Rays Using Confidence-Aware Anomaly Detection' 的科研主题。它们共同构成独一无二的学术指纹。

引用此