TY - JOUR
T1 - Ultrasoft pit-free electrodes
T2 - Conformal low-noise electrochemical interface for ECoG recording
AU - Bai, Ruiyu
AU - Wang, Xuanqi
AU - You, Xiaoli
AU - Yang, Yong
AU - Zhang, Yu
AU - Yu, Quetao
AU - Cao, Jiaxu
AU - Zhou, Xinhua
AU - Jiang, Hao
AU - Chang, Honglong
AU - Wang, Minghao
AU - Yue, Feng
AU - Ji, Bowen
N1 - Publisher Copyright:
© 2026 Elsevier B.V.
PY - 2027/1/15
Y1 - 2027/1/15
N2 - High-fidelity electrocorticography (ECoG) requires intimate microscale coupling and low interfacial impedance at the neural electrode-tissue interface. However, conventional neural electrodes fabricated via standard “substrate-metal-encapsulation” sequences inevitably create recessed “pit” structures with several micrometers in depth. This micro-cavity prolongs ionic diffusion pathways and traps excess noise obeying the inverse frequency power law (1/f noise), severely compromising signal-to-noise ratio (SNR) in low-frequency bands (<10 Hz). Herein, we report an inverse manufacturing sequence to develop an ultrasoft pit-free electrode (UPFE) that completely reshapes the microscale biointerface, meanwhile, we develop the transfer-free integration strategy of the serpentine electrode and the soft silicone base. By eliminating the recessed pit geometry, the UPFE features co-planar recording sites that establish direct, seamless contact with cortical tissue, effectively shortening the ion relocation distance. The inverted fabrication process also generates a roughened Au surface of the UPFE, increasing the surface roughness from 8.75 to 109 nm. And the impedance (@ 1 kHz) of the UPFE is 79.4% lower than the electrodes with “pit” structures. Simultaneously, the transfer-free process enables the polyimide layers to structurally anchor into the underlying ultrasoft silicone base, bypassing the interfacial delamination and modulus mismatch prevalent in conventional transfer-printed electronics. In vivo epidural ECoG recordings in rabbits successfully demonstrated drastically lower contact resistance, suppressed noise power, and superior high-fidelity cortical mapping under deep anesthesia. This pit-free interfacial design offers a fabrication strategy and a robust, low-noise foundation for implantable bioelectronics and advanced brain-computer interfaces (BCIs).
AB - High-fidelity electrocorticography (ECoG) requires intimate microscale coupling and low interfacial impedance at the neural electrode-tissue interface. However, conventional neural electrodes fabricated via standard “substrate-metal-encapsulation” sequences inevitably create recessed “pit” structures with several micrometers in depth. This micro-cavity prolongs ionic diffusion pathways and traps excess noise obeying the inverse frequency power law (1/f noise), severely compromising signal-to-noise ratio (SNR) in low-frequency bands (<10 Hz). Herein, we report an inverse manufacturing sequence to develop an ultrasoft pit-free electrode (UPFE) that completely reshapes the microscale biointerface, meanwhile, we develop the transfer-free integration strategy of the serpentine electrode and the soft silicone base. By eliminating the recessed pit geometry, the UPFE features co-planar recording sites that establish direct, seamless contact with cortical tissue, effectively shortening the ion relocation distance. The inverted fabrication process also generates a roughened Au surface of the UPFE, increasing the surface roughness from 8.75 to 109 nm. And the impedance (@ 1 kHz) of the UPFE is 79.4% lower than the electrodes with “pit” structures. Simultaneously, the transfer-free process enables the polyimide layers to structurally anchor into the underlying ultrasoft silicone base, bypassing the interfacial delamination and modulus mismatch prevalent in conventional transfer-printed electronics. In vivo epidural ECoG recordings in rabbits successfully demonstrated drastically lower contact resistance, suppressed noise power, and superior high-fidelity cortical mapping under deep anesthesia. This pit-free interfacial design offers a fabrication strategy and a robust, low-noise foundation for implantable bioelectronics and advanced brain-computer interfaces (BCIs).
KW - Electrocorticography (ECoG)
KW - Low-noise neural recording
KW - Pit-free interface
KW - Transfer-free integration
KW - Ultrasoft bioelectronics
UR - https://www.scopus.com/pages/publications/105052001172
U2 - 10.1016/j.snb.2026.141010
DO - 10.1016/j.snb.2026.141010
M3 - 文章
AN - SCOPUS:105052001172
SN - 0925-4005
VL - 471
JO - Sensors and Actuators, B: Chemical
JF - Sensors and Actuators, B: Chemical
M1 - 141010
ER -