TY - JOUR
T1 - Thermal-fluid coupling analysis and thermal optimization of servo motor heat dissipation structure
AU - Wang, Hui
AU - Nan, Jieying
AU - Chang, Min
AU - Cao, Hengsheng
N1 - Publisher Copyright:
© 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2026/11
Y1 - 2026/11
N2 - High power density servo motors operating under heavy loads are prone to heat accumulation within enclosed housings, which deteriorates thermal reliability and limits performance. A thermal-fluid coupling enhancement strategy is adopted by introducing a ventilated lower housing to intensify internal-external convective heat exchange while preserving structural protection of the gear train. Results show that compared with the sealed configuration, the ventilated design significantly reduces peak temperatures by 15.66 K, 34.99 K, and 13.65 K, respectively, at 2.942 N·m. Moreover, altitude dependent simulations reveal a competing mechanism between reduced air density and enhanced temperature difference. Although convective heat transfer is weakened due to the decrease in air density, the relatively high and constant freestream velocity mitigates this effect. As a result, under the present operating conditions, the enhancement in temperature difference outweighs the adverse effect associated with the reduction in air density, resulting in a further decrease in the overall servo temperature with increasing altitude. At 8000 m, additional decreases of 8%, 13%, and 7% are found. These findings provide practical guidance for thermal management and structural design of high power-density servo systems.
AB - High power density servo motors operating under heavy loads are prone to heat accumulation within enclosed housings, which deteriorates thermal reliability and limits performance. A thermal-fluid coupling enhancement strategy is adopted by introducing a ventilated lower housing to intensify internal-external convective heat exchange while preserving structural protection of the gear train. Results show that compared with the sealed configuration, the ventilated design significantly reduces peak temperatures by 15.66 K, 34.99 K, and 13.65 K, respectively, at 2.942 N·m. Moreover, altitude dependent simulations reveal a competing mechanism between reduced air density and enhanced temperature difference. Although convective heat transfer is weakened due to the decrease in air density, the relatively high and constant freestream velocity mitigates this effect. As a result, under the present operating conditions, the enhancement in temperature difference outweighs the adverse effect associated with the reduction in air density, resulting in a further decrease in the overall servo temperature with increasing altitude. At 8000 m, additional decreases of 8%, 13%, and 7% are found. These findings provide practical guidance for thermal management and structural design of high power-density servo systems.
KW - Heat dissipation
KW - Servo motor
KW - Structure design
KW - Thermal-fluid coupling
UR - https://www.scopus.com/pages/publications/105051974612
U2 - 10.1016/j.icheatmasstransfer.2026.112721
DO - 10.1016/j.icheatmasstransfer.2026.112721
M3 - 文章
AN - SCOPUS:105051974612
SN - 0735-1933
VL - 180
JO - International Communications in Heat and Mass Transfer
JF - International Communications in Heat and Mass Transfer
M1 - 112721
ER -