Synthesis of pseudo-CT images from pelvic MRI images based on an MD-CycleGAN model for radiotherapy

  • Hongfei Sun
  • , Qianyi Xi
  • , Rongbo Fan
  • , Jiawei Sun
  • , Kai Xie
  • , Xinye Ni
  • , Jianhua Yang
  • Northwestern Polytechnical University Xian
  • The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University
  • Nanjing Medical University

科研成果: 期刊稿件文章同行评审

32 引用 (Scopus)

摘要

Objective. A multi-discriminator-based cycle generative adversarial network (MD-CycleGAN) model is proposed to synthesize higher-quality pseudo-CT from MRI images. Approach. MRI and CT images obtained at the simulation stage with cervical cancer were selected to train the model. The generator adopted DenseNet as the main architecture. The local and global discriminators based on a convolutional neural network jointly discriminated the authenticity of the input image data. In the testing phase, the model was verified by a fourfold cross-validation method. In the prediction stage, the data were selected to evaluate the accuracy of the pseudo-CT in anatomy and dosimetry, and they were compared with the pseudo-CT synthesized by GAN with the generator based on the architectures of ResNet, sUNet, and FCN. Main results. There are significant differences (P < 0.05) in the fourfold cross-validation results on the peak signal-to-noise ratio and structural similarity index metrics between the pseudo-CT obtained based on MD-CycleGAN and the ground truth CT (CTgt). The pseudo-CT synthesized by MD-CycleGAN had closer anatomical information to the CTgt with a root mean square error of 47.83 ± 2.92 HU, a normalized mutual information value of 0.9014 ± 0.0212, and a mean absolute error value of 46.79 ± 2.76 HU. The differences in dose distribution between the pseudo-CT obtained by MD-CycleGAN and the CTgt were minimal. The mean absolute dose errors of Dosemax, Dosemin, and Dosemean based on the planning target volume were used to evaluate the dose uncertainty of the four pseudo-CT. The u-values of the Wilcoxon test were 55.407, 41.82, and 56.208, and the differences were statistically significant. The 2%/2 mm-based gamma pass rate (%) of the proposed method was 95.45 ± 1.91, and the comparison methods (ResNet_GAN, sUnet_GAN, and FCN_GAN) were 93.33 ± 1.20, 89.64 ± 1.63, and 87.31 ± 1.94, respectively. Significance. The pseudo-CT images obtained based on MD-CycleGAN have higher imaging quality and are closer to the CTgt in terms of anatomy and dosimetry than other GAN models.

源语言英语
文章编号035006
期刊Physics in Medicine and Biology
67
3
DOI
出版状态已出版 - 7 2月 2022

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

指纹

探究 'Synthesis of pseudo-CT images from pelvic MRI images based on an MD-CycleGAN model for radiotherapy' 的科研主题。它们共同构成独一无二的指纹。

引用此