跳到主要导航 跳到搜索 跳到主要内容

Series arc fault detection via arcing physical characteristics-guided feature extraction: a dual-signal multi-timescale method

  • Northwestern Polytechnical University Xian

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

Series arc faults (SAFs) are a primary cause of electrical fires in building distribution systems, requiring reliable detection to mitigate fire risks and ensure operational safety. Existing methods, though effective under simplified scenarios, suffer from false alarms and missed detections in complex scenarios involving diverse load types, circuit topologies, arc-generating modes, and arc-like conditions. To address the issues, this paper proposes a SAF detection method that integrates a dual-signal multi-timescale feature extraction framework, an arc fault decision tree, and arc fault decision criteria. Firstly, an experimental platform simulating SAFs in building distribution systems is established, and the arcing characteristics are analyzed through key electrical parameters—arc voltage, current, and zero-sequence current coupling signal—across four stages: arc-igniting, arcing, arc-extinguishing, and zero-current under different arc-generating modes. Secondly, based on these characteristics, with a particular focus on the current and zero-sequence current coupling signal, a comprehensive arc fault feature set is constructed by extracting features from both single-cycle and multi-cycle perspectives. Thirdly, the arc fault decision tree is trained using the constructed feature set, and the arc fault decision criteria are designed based on the persistence characteristics of arc faults. Finally, the superiority of the proposed method is demonstrated through offline tests, online verification on a self-developed prototype, anti-interference experiments, and a comparative analysis. Experimental results show that the proposed method achieves a detection accuracy of 99.20 % under test conditions encompassing thirteen loads, four circuit topologies, and two arc-generating modes, outperforming five representative benchmark methods under identical test conditions. Furthermore, during 360 online tests covering both training conditions and previously unseen real-world operating conditions, the proposed method satisfied standard detection time requirements in 354 tests while maintaining zero false alarms under arc-like conditions such as load switching.

源语言英语
文章编号111385
期刊International Journal of Electrical Power and Energy Systems
173
DOI
出版状态已出版 - 12月 2025

指纹

探究 'Series arc fault detection via arcing physical characteristics-guided feature extraction: a dual-signal multi-timescale method' 的科研主题。它们共同构成独一无二的指纹。

引用此