TY - JOUR
T1 - Scoliotic imaging with a novel double-sweep 2.5-dimensional extended field-of-view ultrasound
AU - Huang, Qinghua
AU - Deng, Qifeng
AU - Li, Le
AU - Yang, Junlin
AU - Li, Xuelong
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/8
Y1 - 2019/8
N2 - Extended field-of-view ultrasound (US EFOV) imaging is a technique used extensively in the clinical field to attain interpretable panorama of anatomy; 2.5-D US EFOV has recently been proposed for spine imaging. In the original 2.5-D US EFOV, it makes use of a six degrees-of-freedom positional sensor attached to the US probe to record the corresponding position of each B-scan. By combining the positional information and the B-scan images, the 2.5-D EFOV can reconstruct a panorama on a curved image plane when the scanning trajectory of the US probe is curved. In this paper, an improved method based on the Bezier interpolation is proposed to better reconstruct 2.5-D US EFOV imaging, producing the panoramas with smoother texture and higher quality. To make it more applicable for scoliosis patients, we designed a novel method called double-sweep 2.5-D EFOV to better image the spinal tissues and easily compute the Cobb angle. In vitro and in vivo experiments demonstrated that the 2.5-D EFOV images obtained by the proposed method can present anatomical structures of the scanning region accurately.
AB - Extended field-of-view ultrasound (US EFOV) imaging is a technique used extensively in the clinical field to attain interpretable panorama of anatomy; 2.5-D US EFOV has recently been proposed for spine imaging. In the original 2.5-D US EFOV, it makes use of a six degrees-of-freedom positional sensor attached to the US probe to record the corresponding position of each B-scan. By combining the positional information and the B-scan images, the 2.5-D EFOV can reconstruct a panorama on a curved image plane when the scanning trajectory of the US probe is curved. In this paper, an improved method based on the Bezier interpolation is proposed to better reconstruct 2.5-D US EFOV imaging, producing the panoramas with smoother texture and higher quality. To make it more applicable for scoliosis patients, we designed a novel method called double-sweep 2.5-D EFOV to better image the spinal tissues and easily compute the Cobb angle. In vitro and in vivo experiments demonstrated that the 2.5-D EFOV images obtained by the proposed method can present anatomical structures of the scanning region accurately.
KW - 2.5-D extended field-of-view (EFOV)
KW - Bezier interpolation
KW - double sweep
KW - spine imaging
KW - ultrasound (US) imaging
UR - https://www.scopus.com/pages/publications/85070283391
U2 - 10.1109/TUFFC.2019.2920422
DO - 10.1109/TUFFC.2019.2920422
M3 - 文章
C2 - 31170068
AN - SCOPUS:85070283391
SN - 0885-3010
VL - 66
SP - 1304
EP - 1315
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 8
M1 - 8727905
ER -