TY - JOUR
T1 - Quantitative analysis of heat generation mechanisms in induction welding of CF/PEEK laminates with different ply orientations
AU - Wang, Shiyu
AU - Zhou, Yanan
AU - Guo, Qihua
AU - Liu, Ruixia
AU - Li, Mengjuan
AU - Yan, Yu
AU - Fu, Rao
AU - Hou, Xiao
N1 - Publisher Copyright:
Copyright © 2026. Published by Elsevier Ltd.
PY - 2026/9
Y1 - 2026/9
N2 - Induction welding of thermoplastic composites offers substantial application potential, yet uncertainty in the heat generation mechanisms at the welding interface severely hinders uniform temperature field control. This study presents a quantitative methodology to decouple the heat generation mechanisms in CF/PEEK laminates with varying ply angles. Four stacking configurations ([0/30]6, [0/45]6, [0/60]6, and [0/90]6) were characterized for their electrical and thermal properties. A microscale heat generation model was established to distinguish the contributions of fiber heating, contact resistance heating, and dielectric hysteresis. Results reveal that junction heating exceeds fiber heating by 106-107 times. The ratio of dielectric hysteresis to contact resistance heating increases monotonically from 2.0512 to 2.8241 as the layup angle increases from 30° to 90°, with dielectric hysteresis dominating (67.2%-73.9%). This trend is attributed to the significant reduction in interlaminar contact resistivity with increasing angle, which diminishes contact resistance heating efficiency and relatively enhances the dominant role of dielectric hysteresis. An angle-dependent compensation coefficient method is proposed to enable quantitative conversion of heat generation efficiency across different layups. Furthermore, a transient three-dimensional finite element model incorporating layup angle is developed and validated, overcoming the conventional limitation to orthogonal layups. This work provides a robust theoretical and simulation framework for process optimization and temperature homogenization in induction welding of thermoplastic composites.
AB - Induction welding of thermoplastic composites offers substantial application potential, yet uncertainty in the heat generation mechanisms at the welding interface severely hinders uniform temperature field control. This study presents a quantitative methodology to decouple the heat generation mechanisms in CF/PEEK laminates with varying ply angles. Four stacking configurations ([0/30]6, [0/45]6, [0/60]6, and [0/90]6) were characterized for their electrical and thermal properties. A microscale heat generation model was established to distinguish the contributions of fiber heating, contact resistance heating, and dielectric hysteresis. Results reveal that junction heating exceeds fiber heating by 106-107 times. The ratio of dielectric hysteresis to contact resistance heating increases monotonically from 2.0512 to 2.8241 as the layup angle increases from 30° to 90°, with dielectric hysteresis dominating (67.2%-73.9%). This trend is attributed to the significant reduction in interlaminar contact resistivity with increasing angle, which diminishes contact resistance heating efficiency and relatively enhances the dominant role of dielectric hysteresis. An angle-dependent compensation coefficient method is proposed to enable quantitative conversion of heat generation efficiency across different layups. Furthermore, a transient three-dimensional finite element model incorporating layup angle is developed and validated, overcoming the conventional limitation to orthogonal layups. This work provides a robust theoretical and simulation framework for process optimization and temperature homogenization in induction welding of thermoplastic composites.
KW - COMSOL geometric model
KW - Heating mechanisms
KW - Induction welding
KW - Temperature prediction model
KW - Thermoplastic composites
UR - https://www.scopus.com/pages/publications/105046961969
U2 - 10.1016/j.polymertesting.2026.109311
DO - 10.1016/j.polymertesting.2026.109311
M3 - 文章
AN - SCOPUS:105046961969
SN - 0142-9418
VL - 162
JO - Polymer Testing
JF - Polymer Testing
M1 - 109311
ER -